X-ray structure determination at low resolution
نویسندگان
چکیده
As an example of structure determination in the 3.5-4.5 A resolution range, crystal structures of the ATPase p97/VCP, consisting of an N-terminal domain followed by a tandem pair of ATPase domains (D1 and D2), are discussed. The structures were originally solved by molecular replacement with the high-resolution structure of the N-D1 fragment of p97/VCP, whereas the D2 domain was manually built using its homology to the D1 domain as a guide. The structure of the D2 domain alone was subsequently solved at 3 A resolution. The refined model of D2 and the high-resolution structure of the N-D1 fragment were then used as starting models for re-refinement against the low-resolution diffraction data for full-length p97. The re-refined full-length models showed significant improvement in both secondary structure and R values. The free R values dropped by as much as 5% compared with the original structure refinements, indicating that refinement is meaningful at low resolution and that there is information in the diffraction data even at approximately 4 A resolution that objectively assesses the quality of the model. It is concluded that de novo model building is problematic at low resolution and refinement should start from high-resolution crystal structures whenever possible.
منابع مشابه
X-Ray Crystal Structure of [N, N'-bis(4-Methoxysalicylidene) -2, 3-Dimethylaminopropane] Copper(II) Ethanol Solvate
The crystal structure of the title Schiff base complex is obtained by single-crystal X-ray diffraction data.The solid state structure determination reveals that the coordination geometry around the copper(II) center istetrahedrally distorted square-planar. The crystal packing shows one dimensional infinite chains which arisesfrom the intermolecular interaction and stabilize the crystal packing.
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملBiotechnological Production of Cellulose by Gluconacetobacter Xylinus from Agricultural Waste
The purpose of this study was to utilize low quality date syrup, a rich and available source of nutrient in Iran, for the production of bacterial cellulose using Gluconacetobacter xylinus. Static batch fermentationfor the purpose of cellulose production by G. xylinus (PTCC, 1734) was studied using low quality date syrupand sucrose solution (Bx. 10%) as fermentation media at 28°C. Re...
متن کاملBinuclear Nickel(II) Complex Containing 6-Methyl-2,2'-bipyridine and Chloride Ligands: Synthesis, Characterization, Thermal Analyses, and Crystal Structure Determination
A new binuclear complex of [{NiCl(6-mbipy)}2(μ-Cl)2] (1) was prepared from the reaction of NiCl2.6H2O and 6-methyl-2,2'-bipyridine (6-mbipy) in a mixture of methanol and acetonitrile. Suitable crystals of 1 for X-ray diffraction measurement were obtained by slow evaporation of the resulted green solution at room ...
متن کاملX-ray Charge-Dens Study of 5-Chloro-8-hydroxy-6-methyloaphthalene-l.4-dione: A Hydroxynaphthoquinone Derivative
The X-ray charge density analysis of a hydroxynaphthoquinnne derivative was obtained by multipolar Hansen-Coppens formalism refinement through high resolution X-ray diffraction data at 100(1) K. The molecularproperties of the title compound resulted from the combined experimental and the quantum theory of atoms inmolecules (QTAIM) studies. The topological properties of the covalent bonds and of...
متن کامل