Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement
نویسندگان
چکیده
BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A comparative study of the accuracy of extramedullary and intramedullary tibial cutting guides was carried out in 92 megaprosthetic knee replacements for distal femoral tumors. For the proximal tibia cut for tibial component placement, an extramedullary guide was used in 65 patients and an intramedullary guide was used in 27 patients. Tibial component alignment angles were measured in postoperative X-rays with the help of CAD software. RESULTS There was more varus placement in coronal plane with extramedullary cutting guide (-1.18 +/- 2.4 degrees) than the intramedullary guide (-0.34 +/- 2.31 degrees) but this did not reach statistical significance. The goal of 90 +/- 2 degrees alignment of tibial component was achieved in 54% of patients in the extramedullary group versus 67% in the intramedullary group. In terms of sagittal plane alignment, extramedullary guide showed less accurate results (2.09 +/- 2.4 degrees) than intramedullary guide (0.50 +/- 3.80 degrees) for tibial component alignment, though 78% of patients were aligned within the goal of 0-5 degrees of tibial slope angle in extramedullary group versus 63% in intramedullary group. The mean error in the measurements due to rotation of the knee during taking the X-rays was less than 0.1 degrees and distribution of the X-rays with the rotation of knee was similar in both the groups. CONCLUSIONS Overall, in megaprosthetic knee replacement intramedullary guides gave more accurate results in sagittal plane and exhibited similar variability as of extramedullary guides in coronal plane.
منابع مشابه
Extramedullary versus intramedullary tibial alignment technique in total knee arthroplasty: A meta-analysis of randomized controlled trials
The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values o...
متن کاملTotal Ankle Arthroplasty Comparison of Extramedullary Versus Intramedullary Referencing for Tibial Component Alignment in
Background: The majority of total ankle arthroplasty (TAA) systems use extramedullary alignment guides for tibial component placement. However, at least 1 system offers intramedullary referencing. In total knee arthroplasty, studies suggest that tibial component placement is more accurate with intramedullary referencing. The purpose of this study was to compare the accuracy of extramedullary re...
متن کاملExtramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment.
We undertook a prospective, randomised study of 135 total knee arthroplasties to determine the most accurate and reliable technique for alignment of the tibial prosthesis. Tibial resection was guided by either intramedullary or extramedullary alignment jigs. Of the 135 knees, standardised postoperative radiographs suitable for assessment were available in 100. Correct tibial alignment was found...
متن کاملIntramedullary versus extramedullary alignment of the tibial component in the Triathlon knee
BACKGROUND Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. METHOD A comparison of intramedullary versus extramedullary align...
متن کاملAlignment of the tibial component in total knee arthroplasty procedures using an intramedullary or extramedullary guide: double-blind randomized prospective study☆
OBJECTIVES To evaluate the results obtained through using an intramedullary or extramedullary guide for sectioning the tibia in total knee arthroplasty procedures, with a view to identifying the accuracy of these guides and whether one might be superior to the other. METHODS This was a randomized double-blind prospective study on 41 total knee arthroplasty procedures performed between August ...
متن کامل