Pulse-height loss in the signal readout circuit of compound semiconductor detectors

نویسندگان

  • M. Nakhostin
  • K. Hitomi
چکیده

Compound semiconductor detectors such as CdTe, CdZnTe, HgI2 and TlBr are known to exhibit large variations in their charge collection times. This paper considers the effect of such variations on the measurement of induced charge pulses by using resistive feedback charge-sensitive preamplifiers. It is shown that, due to the finite decaytime constant of the preamplifiers, the capacitive decay during the signal readout leads to a variable deficit in the measurement of ballistic signals and a digital pulse processing method is employed to correct for it. The method is experimentally examined by using sampled pulses from a TlBr detector coupled to a charge-sensitive preamplifier with 150 μs of decay-time constant and 20 % improvement in the energy resolution of the detector at 662 keV is achieved. The implications of the capacitive decay on the correction of charge-trapping effect by using depth-sensing technique are also considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شبیه سازی یک آشکارساز تناسبی میکرو نواری برای آشکارسازی گاز رادن و دختران با کد مونت کارلو (MCNPX)

Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...

متن کامل

Beam splash effects on ATLAS silicon microstrip detectors evaluated using 1-w Nd :YAG laser

On an incident of accelerator beam loss, the tracking detector located close to the beam line is subjected to receive intensive radiation in a short period. We used a 1-W focused Nd :YAG laser and simulated the effects on the ATLAS microstrip detector. The laser corresponds to intensity of up to 1 10 mips=pulse with a pulse width of about 10 ns. We observed breaks on Al strips on extreme condit...

متن کامل

High Resolution X-Ray Spectroscopy with Compound Semiconductor Detectors and Digital Pulse Processing Systems

The advent of semiconductor detectors has revolutionized the broad field of X-ray spectroscopy. Semiconductor detectors, originally developed for particle physics, are now widely used for X-ray spectroscopy in a large variety of fields, as X-ray fluorescence analysis, X-ray astronomy and diagnostic medicine. The success of semiconductor detectors is due to several unique properties that are not...

متن کامل

Signal-to-Noise in Silicon Microstrip Detectors with Binary Readout

We report the results of a beam test using double-sided ACcoupled silicon microstrip detectors with binary readout, i.e., a readout where the signals are discriminated in the front-end electronics and only the hit location as kept. For strip pitch between 50μm and 200μm, we determine the efficiency and the noise background as function of threshold setting. This allows us to reconstruct the Land...

متن کامل

Improvement of Energy Characteristics of Semiconductor Detectors Using Genetic Algorithms

A new charge loss correction method using genetic algorithms (GA) has been proposed to improve gamma ray energy spectrum characteristics of CdZnTe detectors. The correction method is based on the analysis of signal waveform shapes. GA recognizes the charge generation places for each signal and provides the related corrective factors of the pulse heights; the corrected energy spectrum was obtain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018