Design and Optimization of SiON Ring Resonator-Based Biosensors for Aflatoxin M1 Detection
نویسندگان
چکیده
In this article, we designed and studied silicon oxynitride (SiON) microring-based photonic structures for biosensing applications. We designed waveguides, directional couplers, and racetrack resonators in order to measure refractive index changes smaller than 10-6 refractive index units (RIU). We tested various samples with different SiON refractive indexes as well as the waveguide dimensions for selecting the sensor with the best performance. Propagation losses and bending losses have been measured on test structures, along with a complete characterization of the resonator's performances. Sensitivities and limit of detection (LOD) were also measured using glucose-water solutions and compared with expected results from simulations. Finally, we functionalized the resonator and performed sensing experiments with Aflatoxin M1 (AFM1). We were able to detect the binding of aflatoxin for concentrations as low as 12.5 nm. The results open up the path for designing cost-effective biosensors for a fast and reliable sensitive analysis of AFM1 in milk.
منابع مشابه
Numerical Modeling of a Metamaterial Biosensor for Cancer Tissues Detection
In this paper, the numerical design and simulate a biosensor to detect tumors and cancerous tissues by using metamaterial structures in the microwave regime are presented. The presented structure consists of a microstrip transmission line and a split ring resonator (SRR) that form a bandpass filter and has a unique resonance frequency. Given that cancerous tissues have larger volumes of water t...
متن کاملAsymmetric Mach–Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection
In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si₃N₄ Asymmetric Mach-Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab'). We measured a best volumetric sensitivity of 10⁴ rad/RIU, leading to a Limit of Detection below 5 × 10(-7) RIU. On sensors functionalized with Fab', we performed specific and non-specific sensing measureme...
متن کاملThe New Design and Simulation of an Optical Add Drop Filter Based On Hexagonal Photonic Crystal Single Ring Race Track Resonator
In this paper, using annular resonator we have designed an adding and dropping filter light based ontwo-dimensional photonic crystals. The shape of ring resonator filter adding and dropping that wehave proposed is Race Track. This filter has a hexagonal lattice structure of silicon bars withrefractive index 3/46 that is located in the context of air with refractive index 1. Transmissionefficien...
متن کاملFabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks
Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...
متن کاملDesign of a new narrow band channel drop filter based on photonic crystal ring resonator
In this design an optical ring resonator are embedded between two Horizontal input and output waveguides which has 4 orbitals around the center of the resonator so that each orbital consists of 8 rods with different size in which radius of larger orbitals rods are bigger than radius of smaller orbitals rods. The analysis of simulation results showed the proposed filter has the transmission effi...
متن کامل