Twelve-Month Follow-up of Lumbar Spine Range of Motion Following Intervertebral Disc Replacement Using Radiostereometric Analysis

نویسندگان

  • Nathaniel R. Ordway
  • Amir H. Fayyazi
  • Celeste Abjornson
  • Jerry Calabrese
  • Soo-An Park
  • Bruce Fredrickson
  • Kenneth Yonemura
  • Hansen A. Yuan
چکیده

BACKGROUND Many clinical studies have focused on clinical pain scores and less on kinematics following intervertebral disc replacement. Although flexion and extension of the motion segment can be measured on lateral X-rays, measuring lateral bending and axial rotation of the device is extremely difficult on plain radiography. This study was designed to measure, using radiostereometric analysis (RSA), the postoperative range of motion of the spinal segment following placement of ProDisc-L interbody device (Synthes Spine, West Chester, Pennsylvania). METHODS Twelve patients (15 discs) with a ProDisc-L intervertebral disc replacement were followed postoperatively at 1.5, 3, 6, and 12 months with both clinical and RSA examinations. For follow-up RSA analysis, 4 to 5 tantalum beads were inserted into the vertebrae adjacent to the surgical level during surgery. Standing biplanar films were collected during follow-up, and the ranges of motion (ROM) (sagittal and coronal bending) of the adjacent vertebrae were determined by RSA. RESULTS Based on the clinical surveys, this group of patients had similar outcomes compared to larger clinical populations. The flexion/extension ROM with the disc replacement averaged 2.5° at 6 weeks and increased over the follow-up period to 6.6° at 6 months. The lateral bending ROM with the disc replacement remained consistent over the 4 time points and averaged 3.0°. The motion at the level of the L4-5 vertebrae following disc replacement was greater across all time points than the motion at the L5-S1 level for both sagittal (5.9° versus 2.1°) and coronal (4.2° versus 0.6°) bending. CONCLUSIONS In this study, the amount of RSA-measured segmental flexion/extension ROM for those with disc replacement was similar to other studies using plain radiography. In lateral bending, the amount of motion with disc replacement was less than the typical 6°-16° reported for normal ROM. CLINICAL RELEVANCE This is the first published study evaluating the in vivo kinematics of artificial disc replacement using RSA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Paradoxical and Coupled Motions Following Lumbar Total Disc Replacement

BACKGROUND Maintenance of segmental motion following lumbar total disc replacement (LTDR) is one of the theoretical advantages of spinal arthroplasty. This in vivo study examined paradoxical and coupled motions during sagittal plane movements following disc arthroplasty and compared these motions with those measured following lumbar discectomy. METHODS Ten patients following LTDR using ProDis...

متن کامل

Comparison the Recurrence Rate of Intervertebral Disc Herniation in Two Surgical Methods of Hemi laminectomy and Partial Laminectomy

Background & Aims: Between 5% and 15% of patients with low back pain suffer from lumbar disc herniation, so intervertebral disc disease is one of the most common causes of low back pain. Surgical intervention for lumbar disc herniation is recommended in patients with severe symptoms and has hopeful results. Although surgery can reduce pain and improve physical function in the short term, its lo...

متن کامل

ProDisc artificial total lumbar disc replacement: introduction and early results from the United States clinical trial.

STUDY DESIGN Multicenter prospective randomized study of artificial disc replacement (ProDisc) versus circumferential fusion (standard of care) for one- and two-level degenerative disc disease. This is an interim analysis on patients seen at the Spine Institute Saint John's Health Center, Santa Monica, California. OBJECTIVES To evaluate early pain and functional outcomes of patients treated w...

متن کامل

Total disc replacement in the treatment of lumbar discogenic pain with disc herniation: a prospective clinical study.

BACKGROUND Biomechanical benefits of Total Disc Replacement (TDR) including both the restoration of normal segmental range of motion and the prevention of physiological lumbar lordosis encourage spine surgeons to perform TDR for lumbar disc disease. METHODS A total of twenty patients (mean age: 39.5) who had degenerative disc disease with unilateral disc herniation were operated on between 20...

متن کامل

Stability After Anterior Lumbar Fusion with Interbody Cages: A Radiostereometric Evaluation

Background: Interbody cage stabilization as a stand-alone procedure in lumbar spine fusion is questioned due to inconsistent mechanical effects registered in human cadaveric studies. Even segmental mobility exceeding the normal range of motion is described after cage implantation. For the anterior interbody cage fusion, this potential, undesired destabilization is explained by the resection of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008