Safety of Silastic Sheet for Orbital Wall Reconstruction

نویسندگان

  • Seong June Moon
  • Hyun Suk Suh
  • Bo Young Park
  • So Ra Kang
چکیده

BACKGROUND Many implants are being used for the reconstruction of orbital wall fractures. The effect of the choice of implant for the reconstruction of an orbital wall fracture on the surgical outcome is under debate. The purpose of this article is to compare the outcomes of orbital wall reconstruction of small orbital wall fractures on the basis of the implants used. METHODS The authors conducted a retrospective study using electronic databases. Between March 2001 and December 2012, 461 patients with orbital wall fractures were included in this study. Among them, 431 patients in whom the fracture size was less than 300 mm(2) were analyzed. The fracture size was calculated using computed tomography scans of the orbit in the sagittal and coronal images. Cases in which the fracture size was less than 300 mm(2) were included in this study. RESULTS One hundred and twenty-nine patients were treated with silastic sheets; 238 patients were treated with titanium meshes; and absorbable meshes were used in the case of 64 patients. Overall, 13 patients required revision, and the revision rate was 3.0%. The revision rate of the silastic sheet group was 5.4%. In the multivariable analysis, the revision rate of the group reconstructed with silastic sheets was highly statistically significant (P=0.043, odds ratio=3.65). However, other factors such as age, sex, fracture type, and fracture size were not significant. CONCLUSIONS Reconstruction of orbital wall fractures with silastic sheets may cause more complications than that with other materials such as titanium meshes and absorbable meshes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Silastic Sheet found during Endoscopic Transnasal Dacryocystorhinostomy for Acute Dacryocystitis

PURPOSE To report the case of a silastic sheet that was found during an endoscopic transnasal dacryocystorhinostomy for treatment of acute dacryocystitis with necrosis of the lacrimal sac. METHODS A thirty-two year old male presented with painful swelling on the nasal side of his left lower lid two weeks prior to visiting this clinic. Fourteen years ago, the patient was involved in a traffic ...

متن کامل

Preventing lateral synechia formation after endoscopic sinus surgery with a silastic sheet.

OBJECTIVES To investigate whether the insertion of a Silastic sheet between the middle turbinate and lateral nasal wall can prevent lateral synechia formation when an unstable, floppy middle turbinate results from endoscopic sinus surgery (ESS). DESIGN Prospective study. SETTING University hospital. PATIENTS Thirty patients who developed an unstable, floppy middle turbinate during ESS wer...

متن کامل

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures.

Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the inse...

متن کامل

Computer-assisted design and manufacture of implants in the late reconstruction of extensive orbital fractures.

OBJECTIVE To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures. METHODS We performed a retrospective data review on 29 patients treated for extensive orbital fractures from January 1, 1997, through December 31, 2007, at the University College London Hospitals. The use of a CAD/CAM te...

متن کامل

Preformed vs intraoperative bending of titanium mesh for orbital reconstruction.

OBJECTIVE The most accurate orbital reconstructions result from an anatomic repair of the premorbid orbital architecture. Many different techniques and materials have been used; unfortunately, there is currently no optimal method. This study compares the use of preformed vs intraoperative bending of titanium mesh for orbital reconstruction in 2-wall orbital fractures. STUDY DESIGN Cadaver-bas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2014