Two- and Three-Dimensional Anatomy of Paranasal Sinuses in Arabian Foals

نویسندگان

  • Sadullah BAHAR
  • Durmus BOLAT
  • Mustafa Orhun DAYAN
  • Yahya PAKSOY
چکیده

The 2- and 3-dimensional (3D) anatomy and the morphometric properties of the paranasal sinuses of the foal have received little or no attention in the literature. The aim of this study was to obtain details of the paranasal sinuses using multiplane CT imaging to create 3D models and to determine morphological and morphometric data for the sinuses using the 3D models. The heads of five female foals were used in this study. The heads were scanned using computed tomography (CT) in the rostrocaudal direction. After the heads had been frozen, anatomical sections were obtained in the scan position. The 3D models of sinuses and the skull were prepared using MIMICS(®). These models were used to assess the surface area and volume of the sinuses, the width, height and orientation of the apertures connecting these sinuses and finally the planar relation of the sinuses with the skull. The right and left sides of all anatomical structures, except the sphenoid sinuses, had symmetric organization on CT images and anatomical sections. The total sinus surface area and volume on both sides were 214.4 cm(2) and 72.9 ml, respectively. The largest and the smallest sinuses were the frontal sinus (41.5 ml) and the middle conchal sinus (0.2 ml), respectively. It was found that the planes bounding the sinuses passed through easily palpable points on the head. In conclusion, 3D modeling in combination with conventional sectional imaging of the paranasal sinuses of the foal may help anatomists, radiologists, clinicians and veterinary students.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomic Reference for Computed Tomography of the Paranasal Sinuses and Their Openings in the Rayini Goat

Objective-  to provide a reference anatomy of the paranasal sinuses of the goat by using computed tomographic modality. Design- Experimented study.   Animals- Five male Rayini goats.   Procedures- CT images were acquired from the head region perpendicular to the hard palate. CT windows were adjusted as necessary to  obtain the optimal image for the paranasal sinuses. The images were studie...

متن کامل

Heritability parameters for some body measurements in Turkish Arabian foals

The aim of the present study was to estimate genetic parameters of body measurements in TurkishArabian foals. Records of wither height, front cannon circumference, heart girth, and body length were usedfor body measurements at birth, 6 months of age, 1-year-old and 2-year-old. Heritability of bodymeasurements of Turkish Arabian foals was estimated by using records of foals sired by stallions wh...

متن کامل

The sinonasal communication in the horse: examinations using computerized three-dimensional reformatted renderings of computed-tomography datasets

BACKGROUND Sinusitis is a common disease in the horse. In human medicine it is described, that obstruction of the sinonasal communication plays a major role in the development of sinusitis. To get spatial sense of the equine specific communication ways between the nasal cavity and the paranasal sinuses, heads of 19 horses, aged 2 to 26 years, were analyzed using three-dimensional (3D) reformatt...

متن کامل

Tailored low dose three-dimensional CT of paranasal sinuses.

A technique for three-dimensional (3D) computed tomography (CT) of the paranasal sinuses was evaluated. The influence of milliamperage and reconstruction algorithms on image quality was studied in a phantom. Eleven patients with bony abnormalities of the paranasal sinuses underwent CT to assess the clinical impact of 3D CT protocol. Contiguous 1.5-mm sections obtained at 120 kVp/175 mA/1.9 sec ...

متن کامل

Image Optimization and reduction of radiation dose in CT of the paranasal sinuses

Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 76  شماره 

صفحات  -

تاریخ انتشار 2014