[CLINICAL UTILITY OF T-SPOT.TB ASSAY WITH T-Cell Xtend REAGENT FOR ACTIVE TUBERCULOSIS DIAGNOSIS IN THE FIELD TEST AT OUR HOSPITAL].

نویسندگان

  • Kenji Nemoto
  • Shuji Oh-ishi
  • Masato Taguchi
  • Kentaro Hyodo
  • Jun Kanazawa
  • Yukiko Miura
  • Takio Takaku
  • Shingo Usui
  • Kenji Hayashihara
  • Takefumi Saito
چکیده

BACKGROUND T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. PURPOSE To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. METHODS A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. RESULTS Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. CONCLUSION In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maintenance of Sensitivity of the T-SPOT.TB Assay after Overnight Storage of Blood Samples, Dar es Salaam, Tanzania

Background. T-SPOT.TB is an interferon gamma release assay for detecting Mycobacterium tuberculosis infection. The requirement to process within 8 hours is constraining, deters use, and leads to invalid results. Addition of T Cell Xtend reagent may allow delayed processing, but has not been extensively field tested. Design. Consecutive AFB smear positive adult tuberculosis patients were prospec...

متن کامل

Validation of increased blood storage times with the T-SPOT.TB assay with T-Cell Xtend reagent in individuals with different tuberculosis risk factors.

We compared the performance of the T-SPOT.TB assay with blood used within 0 to 3.5 h after collection (control) to its performance with blood stored for 0 to 3.5, 5 to 8, 18 to 21, or 31 to 33 h with the addition of T-Cell Xtend (experimental), using samples from 154 participants. The 95.4% concordance between paired specimens indicated that blood can be stored for up to 33 h prior to T-SPOT.TB...

متن کامل

Positive interferon-gamma release assay results are correlated with paradoxical reaction in tuberculous meningitis

Background: Evidence suggests that T cell-based interferon-γ release assays (IGRAs) may be useful for the diagnosis of tuberculosis. The present study aims to investigate the clinical significance of blood T-SPOT.TB assay, a commercially available IGRAs, in tuberculous meningitis (TBM) patients. Methods: Records of consecutive TBM and non-TBM meningitis patients admitted from July 2011 to March...

متن کامل

Utility of T-Cell Interferon-γ Release Assays for Etiological Diagnosis of Classic Fever of Unknown Origin in a High Tuberculosis Endemic Area — a pilot prospective cohort

BACKGROUND Tuberculosis (TB), especially extrapulmonary TB is still the leading cause of fever of unknown origin (FUO) in China. However, diagnosis of TB still remains a challenge. The aim of this study was to evaluate the diagnostic value of T-SPOT.TB for etiological diagnosis of classic FUO in adult patients in a high TB endemic area. METHODS We prospectively enrolled patients presenting wi...

متن کامل

Clinical usefulness of T-SPOT.TB in the diagnosis tuberculosis in emergency patients

Objective To evaluate the diagnostic value of an interferon-gamma release assay T-SPOT.TB in tuberculosis of emergency patients. Methods The emergency patients with suspected tuberculosis received T-SPOT.TB assay in the peripheral blood mononuclear cells(PBMCs). Results T-SPOT.TB assay, PPD, anti-TB antibody test, M tuberculosis polymerase chain reaction, acid-fast bacilli stain and cultures fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kekkaku : [Tuberculosis]

دوره 91 4  شماره 

صفحات  -

تاریخ انتشار 2016