Intramuscular temperature differences between the mid-point and peripheral effective radiating area with ultrasound.
نویسندگان
چکیده
The purpose of the study was to determine whether uniform intramuscular heating is achieved throughout a treatment area 2 times the transducer head at both 1 and 3 MHz. Seven male and three female subjects (Age: 23.6 ± 1.0 yrs, Weight: 83.8 ± 23.2 kg, Site Skinfold: 13.9 ± 7.3 mm) underwent two ultrasound treatments (1 and 3 MHz) in the triceps surae muscle group. Thermocouples were inserted at the midpoint and periphery of the treatment area. Ten minute baseline temperatures were recorded followed by a ten minute ultrasound treatment. Two (site) X 10 (time) repeated measures ANOVAs were separately used to determine significance for 1 and 3 MHz treatments. Post-hoc testing was performed using the Bonferroni adjustment. A significant site-by-time interaction was observed for both the 1 and 3 MHz treatments. From baseline to the end of the treatment, temperature increased approximately 2.62°C and 1.58°C for the midpoint and periphery of the 1 MHz treatment and 5.88°C and 3.64°C for the 3 MHz treatment. The differences in temperature suggest that uniform heating does not occur throughout the treatment area. Key points3 MHz is more effective in raising intramuscular temperature within ERA.Stroke count/rate of transducer may play a factor in heating tissue.Treatment size may alter uniform heating.
منابع مشابه
The Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study
Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملEvaluating the effect of stenosis increase and pulsatile blood pressure on effective stress distribution in viscoelastic finite element model based on carotid artery ultrasound images
The aim of this study is to evaluate the changes of effective stress distribution in plaque by progressing to the stenosis throat and to assess the pulsatile pulse pressure effect on effective stress of a viscoelastic finite-element model of carotid arteries having less and more than 50% stenosis. In-vivo geometries of the arteries were reconstructed using consecutive transverse ultrasound imag...
متن کاملEcological Effects of Climate Factors on Rangeland Vegetation (Case Study: Polour Rangelands)
Climate is the most important factor of plants distribution in global and regional scale. Understanding the current distribution of vegetation cover and its interaction with climate regularity is important for predicting its future. In order to determine the effective climate factors in plant life-form in Polour rangelands in the Damavand summit (2400 to 4100 m above sea level), Iran, a study w...
متن کاملUltrasound-guided cervical periradicular steroid injection for cervical radicular pain: relevance of spread pattern and degree of penetration of contrast medium.
BACKGROUND AND OBJECTIVES Ultrasound-guided cervical periradicular steroid injection (US-CPSI) is an attractive alternate to conventional C-arm guided transforaminal epidural injection for treatment of cervical radicular pain. We compared the technical differences and clinical outcomes between these two techniques. METHODS Following ultrasound-guided needle placement, the extent of contrast m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2008