Improved HPLC Method Using 2,3-naphthalenedicarboxaldehyde as Fluorescent Labeling Agent for Quantification of Histamine in Human Immunoglobulin Preparations

نویسندگان

  • Jung-Hwan Kim
  • In Soo Shin
  • Yoo Kyoung Lee
  • Ho Jung Oh
  • Sang Ja Ban
چکیده

OBJECTIVES To develop and optimize quantitative HPLC method using 2,3-naphthalenedicarboxaldehyde (NDA) after simple and efficient solid phase extraction to determine the histamine in a biopharmaceutical (Histobulin™). METHODS The HPLC method was established using NDA-induced Histobulin and compared with the recently reported HPLC method using o-phthaldehyde (OPA). The validated NDA-applied HPLC method was adjusted to 15 lots of Histobulin and compared by the current lot-release-test method using fluorimetry in recovery of histamine and reproducibility. RESULTS Analyses of six HPLC chromatograms using NDA and OPA each were compared. NDA produced a more stable chromatogram baseline than OPA, and showed better stability. The HPLC analysis was validated in accuracy (91-103%), precision (interday/intraday assay CV ≤2.30%), and linearity of dose-response curve (R(2) ≥ 0.9919). The detection limit was 0.0076 μg/mL and the quantitative limit was 0.0229 μg/mL. The amount of histamine per 12 mg of immunoglobulin was determined to be 0.17 ± 0.016 μg by the HPLC and 0.025 ± 0.013 μg by the current lot-release-test method using fluorimetry. CONCLUSION NDA derivatization showed better stability compared with the OPA method. Therefore the newly established NDA-derivatizated HPLC method may be more suitable than the fluorimetric method in lot-release-tests of biopharmaceuticals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Labeling of Neural Stem Cells with Poly-L-Lysine Coated Super Paramagnetic Nanoparticles for Green Fluorescent Protein Transfection

Background: The magnetic nanoparticle-based transfection method is a relatively new technique for delivery of functional genes to target tissues. We aimed to evaluate the transfection efficiency of rat neural stem cell (NSC) using poly-L-lysine hydrobromide (PLL)-coated super paramagnetic iron oxide nanoparticles (SPION). Methods: The SPION was prepared and coated with PLL as transfection agent...

متن کامل

Indium-111 maltolate complex as a cell labeling agent for SPECT imaging

Introduction: Due to the cell labeling potentials of various metal-maltol complexes, the idea of developing a possible cell labeling imaging agent using single photon emission computed chromatography (SPECT) with[111In]-maltolate complex has been investigated. Methods: [111In] labeled 3-hydroxy-2-methyl-4H-pyran-4-onate ([111In]-maltolate) was prepared using f...

متن کامل

Evaluation of the clearance characteristics of liposomes in the human nose by gamma-scintigraphy

The nasal cavity possesses many advantages as a site for drug delivery, such as, ease of administration, applicability for long term treatments and a large surface area for absorption. One important limiting factor for nasal drug delivery is the limited time available for absorption within the nasal cavity due to mucociliary clearance. Several drug delivery systems including different kinds of ...

متن کامل

Evaluation of the clearance characteristics of liposomes in the human nose by gamma-scintigraphy

The nasal cavity possesses many advantages as a site for drug delivery, such as, ease of administration, applicability for long term treatments and a large surface area for absorption. One important limiting factor for nasal drug delivery is the limited time available for absorption within the nasal cavity due to mucociliary clearance. Several drug delivery systems including different kinds of ...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011