The next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment.

نویسندگان

  • Takashi Azuma
  • Yoshihiko Yokoi
  • Kenji Yamazaki
چکیده

OBJECTIVES Short- and mid-term data regarding the use of precurved, fenestrated endografts have shown that these devices are both safe and effective in carefully selected patients. The first generation of the product was limited to patients with proximal landing zones (LZs) of >20 mm. The next generation of these endografts has been refined to enable the treatment of patients with shorter proximal seal zones (<20 mm), using smaller fenestrations and a greater diversity of skeletons. We reviewed the clinical studies involving the next-generation product and analysed the morphological characteristics of aortic arch aneurysms that were successfully treated. METHODS Next-generation endografts were used to treat 393 patients with aortic arch aneurysms at 35 medical institutions during 2010 and 2011. There were 371 (94%) patients with sealing zones <20 mm and 244 (62%) with sealing zones <15 mm. The proximal sealing length was 2-35 (14.2 ± 5.1) mm. RESULTS Technical success was achieved in 390 (99.2%) patients. Of the treated patient population, 6 patients died, 7 experienced strokes and 17 were subsequently identified to have Type I endoleaks. In cases with proximal LZs <15 mm, the aneurysm was more likely to develop an endoleak. The proximal sealing zones (11 ± 12 vs 9 ± 13 mm) were not significantly associated with the development of endoleaks, but the proximal aortic diameters were (34.0 ± 13.3 vs 36.6 ± 6.3 mm; P < 0.01), in the univariate analysis. In the discriminant analysis, the maximum length of the aneurysm was the only factor that was predictive of Type I endoleaks (73 ± 55 vs 97 ± 59 mm; P < 0.001). CONCLUSIONS The next generation of precurved, fenestrated endografts shows promise as devices for aortic arch aneurysms with a <15-mm proximal sealing zone. These devices have a significant advantage in cases where the LZ has a short neck. However, more refinement is necessary to prevent Type I endoleaks, so that these devices can be used with aortic vessels with large proximal diameters and large aneurysms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term results of endovascular repair for distal arch and descending thoracic aortic aneurysms treated by custom-made endografts: usefulness of fenestrated endografts.

OBJECTIVE We evaluated early and long-term results of atherosclerotic aneurysm repair with custom-made endografts. MATERIALS AND METHODS Eighty-one consecutive patients underwent thoracic endovascular aortic repair with custom-made endografts. Fenestrated grafts were used in 37 patients (45.7%) to maintain blood flow of the neck and a landing zone for as long as possible for distal arch or pr...

متن کامل

Application of the Bolton Relay Device for Thoracic Endografting In or Near the Aortic Arch.

Endovascular correction of aortic arch pathology remains a challenge, with a variety of techniques proposed over the years to minimize complications and enhance the probability of a successful result. A variety of approaches have been developed in order to deal with the aortic arch pathology and its idiosyncrasies. We review potential interventional techniques for the repair of aortic arch path...

متن کامل

Usefulness of fenestrated stent grafts for thoracic aortic aneurysms.

OBJECTIVES Endovascular stent grafts (SGs) comprise a novel therapeutic approach to repairing aortic aneurysms. However, endovascular repair of the aortic arch remains challenging. Generally, the repair of sites with SGs requires an extra-anatomical bypass. We introduced SG repair of the aortic arch with strategically positioned fenestrations for each arch branch in 2006. An extra-anatomical by...

متن کامل

Case Rehearsal in 3D Aortic Models Using Prototypes of the Fenestrated AnacondaTM Custom AAA Stent Graft System

T he Fenestrated AnacondaTM Custom AAA Stent Graft System (Vascutek Ltd.) is intended for the treatment of abdominal aortic aneurysms with an insufficient infrarenal landing zone. The endografts are custom made based on high-resolution, 1 mm slice CTA images. The planning and construction of a fenestrated endograft for complex aortic anatomy is critical when exact positioning of the graft is pa...

متن کامل

Endovascular Repair of Complex Aortic Pathology

Aortic aneurysms are classified as complex based on their extent and involvement of side branches. Complex aortic aneurysms include arch, thoracoabdominal, juxtarenal and suprarenal aortic aneurysms. Open surgical repair carries high morbidity and mortality beyond large tertiary care centers. During the last decade, numerous technological advances have allowed incorporation of side branches usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2013