Biomechanical study of C2 (Axis) fracture: effect of restraint.

نویسندگان

  • E C Teo
  • J P Paul
  • J H Evans
  • H W Ng
چکیده

INTRODUCTION In human, the cervical spine region is very susceptible to impact injury. The complex structures of C1 and C2 serve to transmit the weight of the cranium to the greatly similar structural cervical spine from C3 caudally. Application of sudden disruption forces will detach the junction of the cervico-cranium with the pars interarticularis of the neural arch of C2 from the lower cervical spine by fracturing, as in a "hangman's fracture". Severe falls or blows to the head from heavy objects will cause the fracture of the odontoid process of C2. Many biomechanical studies were conducted based on full restraint of the inferior aspects of isolated C2 to produce odontoid fracture. In this study, two different restraining conditions of C2 were adopted experimentally to determine the absolute fracture load and the corresponding fracture patterns that are common to C2. MATERIALS AND METHODS Nine C2 vertebrae obtained from cadaver spines, ranging from 51 to 80 years, were used. Two specified restraint conditions were employed: (1) fully constrain the posterior element postero-anteriorly up to one-quarter of the inferior facet; and (2) fixing of C2 by a specially-designed rig whereby the body of C2 embedded in the pivoted cup and its inferior facets positioned on top of two lateral plates. Antero-posterior shear force was applied on the anterior articulating facet of the dens until failure. RESULTS These specified restraint conditions had resulted in specific fracture of C2. Antero-posterior shear force ranges from 840 to 1220 N was required to cause fracture across the pars interarticularis under restraint condition 1. Failure load of between 900 and 1500 N was found to cause odontoid fracture under restraint condition 2. These values are in agreement with published data. CONCLUSIONS The biomechanical response of C2 was specific to the mode of restraint conditions of C2. In reality, depending on the force vector applied to the head, precise posture at the time of trauma, spinal geometry, and physical properties, different types of C2 fracture patterns may happen. These findings are of potentials for the biomechanical correlation and validation study of C2 vertebra using analytical approaches, and in the surgical anterior screw fixation of odontoid fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental investigation of failure load and fracture patterns of C2 (axis).

The injury mechanism and magnitude of failure load of C2 fractures are important in the clinical treatment of its fixation. The magnitudes of the failure load of C2 and the mechanism of injury in vivo are uncertain. Accordingly, nine C2 vertebrae obtained from cadaver spines, ranging in age from 51 to 80 years, were used for the study. Special restraint conditions were applied to yield specific...

متن کامل

Effect of Autogenous Omental Free Graft on the Biomechanical Properties of Fracture Healing in Dog

Objective- To evaluate greater omentum as an autogenous free graft in enhancing bone healing.Design- Prospective descriptive trial.Animals- Ten mongrel adult dogs, 3 to 4 years old and weighing 25.2 to 31 kg, assigned into two equal experimental and control groups (5dogs/group), were used.Procedures- Mid-shaft osteotomy on right radius was followed by a partial omentectomy in all dogs. A 30x30 ...

متن کامل

Odontoid process fractures: the role of the ligaments in maintaining stability. A biomechanical, cadaveric study

AIMS We wished to investigate the role of the cervical ligaments in maintaining atlantoaxial stability after fracture of the odontoid process. METHODS We dissected eight fresh-frozen cadaveric cervical spines to prepare the C1 and C2 vertebrae for biomechanical analysis. The C1 and C2 blocks were mounted and biomechanical analysis was performed to test the stability of the C1-C2 complex after...

متن کامل

Biomechanical Assessment of Stabilization of Simulated Type II Odontoid Fracture with Case Study

STUDY DESIGN Researchers created a proper type II dens fracture (DF) and quantified a novel current posterior fixation technique with spacers at C1-C2. A clinical case study supplements this biomechanical analysis. PURPOSE Researchers explored their hypothesis that spacers combined with posterior instrumentation (PI) reduce range of motion significantly, possibly leading to better fusion outc...

متن کامل

Hangman’s Fracture with Concomitant Atlantoaxial Dislocation: a ‎Case Report

Background: Concomitant Hangman’s fracture and atlantoaxial subluxation is a rare phenomenon. Herein, we reported a victim of motor vehicle crash with traumatic spondylolisthesis of the axis and atlantoaxial rotatory dislocation. Case presentation: the patient was a 32 years old female with a chief complaint of severe neck pain and normal neurologic examination except for mild torticollis. Ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2001