Facilitated advancement of the Palmaz-Schatz stent delivery system with the use of an adjacent 0.018" stiff wire.

نویسندگان

  • J F Saucedo
  • D W Muller
  • M Moscucci
چکیده

The 5.0 French Palmaz-Schatz stent delivery system is a relatively bulky, stiff system which can be advanced only over a 0.014" wire. Although crossing failure is rare, advancement of the delivery system through tortuous, rigid vessels may be unsuccessful. We report on four consecutive cases in which the initial advancement of the Palmaz-Schatz stent delivery system was unsuccessful due to vessel tortuosity or vessel angulation. The use of a 0.018" stiff wirer adjacent to the Palmaz-Schatz delivery system, to "straighten" the vessels and to give additional guide catheter support, allowed for the successful advancement and delivery of coronary stents in all four cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Superimposed stents in the management of acute recoil after Palmaz-Schatz stenting.

We report a patient in whom aorto-ostial stenting with a Palmaz-Schatz coronary stent was complicated by significant acute elastic recoil, despite appropriate positioning of the stent and full expansion of a high-pressure, postdilatation balloon. Superimposing a Palmaz biliary stent overcame the inward radial force of this lesion and achieved an adequate lumen.

متن کامل

Coronary stents: In vitro aspects of an angiographic and ultrasound quantification with in vivo correlation.

BACKGROUND The validity of quantitative coronary angiography (QCA) after stent placement has been questioned because the optical density of a metallic stent, added to the density of a contrast-filled lumen, could affect border definition. METHODS AND RESULTS We deployed 3.0- and 4.0-mm Palmaz-Schatz, Wiktor, Multilink, NIR, and InStent stents in precision-cast phantoms. Central lumens of 2.0 ...

متن کامل

Influence of expanded balloon diameter on Palmaz-Schatz stent recoil.

After successful stent implantation, the residual luminal diameter of the stented vessel is usually smaller than the maximal stent-expanded balloon diameter. The goal of this study was to determine whether immediate vessel diameter recoil after Palmaz-Schatz stenting is affected by the final expanding balloon diameter used during stent deployment. Single Palmaz-Schatz balloon expandable stents ...

متن کامل

In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: differential outcome by stent design.

BACKGROUND Despite the routine use of high pressure, coronary stents generally fail to achieve a cross-sectional area (CSA) >60% to 80% of the nominal CSA of their dilating balloon. The extent to which incomplete balloon expansion and postdeflation stent recoil contribute to this failure has not been fully evaluated. METHODS AND RESULTS Thirty-two stents (8 Gianturco-Roubin II, 8 Palmaz-Schat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular diagnosis

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 1996