FreeStyle Lite--a blood glucose meter that requires no coding.

نویسنده

  • Shridhara Alva
چکیده

BACKGROUND Abbott Diabetes Care introduced the FreeStyle Lite blood glucose monitoring system, which simplifies the management of diabetes. The FreeStyle Lite system relies on FreeStyle technology but eliminates the need for coding the meter for individual strip lots. The meter is precoded for the FreeStyle Lite strips. FreeStyle systems use coulometry technology where the glucose signal is calculated from the total charge generated as a result of the glucose reaction in the sample. FreeStyle strip calibration parameters can be controlled by controlling the sample volume. Coulometry technology is less sensitive to measurement conditions such as temperature and hematocrit. FreeStyle chemistry is less sensitive to interference from electroactive compounds. The ability to control calibration parameters coupled to a robust measurement technology enabled the development of a blood glucose monitoring system that does not require coding by the user. METHODS Laboratory studies were performed to determine analytical performance, such as linearity, precision, and sensitivity to operating temperature. Clinical accuracy for finger tip capillary blood testing was assessed with five lots of FreeStyle Lite test strips. FreeStyle Lite results in these studies were compared to the plasma equivalent glucose values of finger tip blood samples measured by the Yellow Springs Instrument glucose analyzer. RESULTS In the analytical performance evaluation, repeatability (within-run precision) of the FreeStyle Lite system showed an average standard deviation of 3.4 mg/dl (0.19 mmol/liter) at glucose concentrations <100 mg/dl (<5.56 mmol/liter) and an average coefficient of variation of 4.3% at glucose concentrations > or =100 mg/dl (> or =5.56 mmol/liter). Linearity demonstrated across the measuring range of the FreeStyle Lite system was 20-500 mg/dl (1.1-27.8 mmol/liter) with r(2) > 0.99. The FreeStyle Lite system was also shown to maintain accuracy across the operating temperature range of 4 to 40 degrees C. CONCLUSIONS The FreeStyle Lite system has good analytical performance and clinical accuracy. While simplifying the process of blood glucose monitoring, the FreeStyle Lite system continues to provide the performance that users have come to expect from FreeStyle products.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the FreeStyle Lite Blood Glucose Monitoring System

Method: Clinical accuracy for fingertip capillary blood testing was assessed at three diabetes clinics with three lots of FreeStyle Lite test strips. At the same clinics, lay user performance and alternative site testing (on forearm, upper arm, palm thenar, palm hypothenar, back of the hand, calf and thigh) were also evaluated. FreeStyle Lite system results in these studies were compared to the...

متن کامل

Datalog LITE : Temporal versus deductive reasoning

In this paper we show that Datalog is well-suited as a temporal veriication language. Datalog is a well-known database query language relying on the logic programming paradigm. We introduce Datalog LITE, a fragment of Datalog with negation, and present a linear time model checking algorithm for Datalog LITE. We show that Datalog LITE subsumes temporal languages such as CTL and the alternation-f...

متن کامل

Semantic Web Service Automation with Lightweight Annotations?

Web services, both RESTful and WSDL-based, are an increasingly important part of the Web. With the application of semantic technologies, we can achieve automation of the use of those services. In this paper, we present WSMO-Lite and MicroWSMO, two related lightweight approaches to semantic Web service description, evolved from the WSMO framework. WSMO-Lite uses SAWSDL to annotate WSDL-based ser...

متن کامل

Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices.

BACKGROUND It has been demonstrated that dynamic electrochemistry can be used to correct blood glucose measurement results for potentially interfering conditions, such as humidity, hematocrit (HCT) variations, and ascorbic acid. The purpose of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of blood glucose meters applying different meas...

متن کامل

Hematocrit interference of blood glucose meters for patient self-measurement.

BACKGROUND Abnormal hematocrit levels may interfere with glucose readings of patient self-assessment blood glucose (BG) meters. The aim of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of BG meters applying different measurement technologies. METHODS Venous heparinized blood was manipulated to contain three different BG concentration...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2008