The Caluculation of 3D Saptial Dose Distribution Around a Shielded Vaginal Cylinder with Iridium-192 Source Calculated by using Monte Carlo Code EGS4
نویسندگان
چکیده
According to our previous study on the dose distribution around a shielded vaginal cylinder with a high-intensity Ir source by using EGS4 code, the more detailed 3D-simulation model was established in this work. The results obtained by the 3D-simulation model were compared with those measured by ion chamber in previous work and evaluated by the existing treatment planning system. These results show good agreement. Furthermore, the 3D spatial dose distribution around a unit intensity Ir source was calculated at each probable position in the vaginal cylinder with 90 , 180 , 270 tungsten shield and no shield cases. Those results save as a database which could be accessed through the graphical user interface developed by IDL to display dose distributions in 1D, 2D, and 3D plot under any combination of source intensity at each position, and shielding situation. It demonstrates a prototype of the brachytherapy treatment planning system based on the Monte Carlo EGS4 code.
منابع مشابه
Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom
Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...
متن کاملMonte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom
Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...
متن کاملDose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP
Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...
متن کاملEvaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources
Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments. Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...
متن کاملMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...