On-Chip Mesoporous Functionalized Magnetic Microspheres for Protein Sequencing by Extended Bottom-up Mass Spectrometry.

نویسندگان

  • Natalia Gasilova
  • Kristina Srzentić
  • Liang Qiao
  • Baohong Liu
  • Alain Beck
  • Yury O Tsybin
  • Hubert H Girault
چکیده

A limited amount and extreme concentration variability of proteomic-related samples require efficient analyte preconcentration and purification prior to the mass spectrometry (MS)-based analysis. Preferably, these steps should be coupled online with chosen fractionation and detection techniques for the minimization of the sample loss. To realize such sample pretreatment, herein, an on-chip solid-phase extraction-gradient elution-tandem mass spectrometry (SPE-GEMS/MS) is introduced. This technique combines in a microfluidic format online sample preconcentration/purification on SPE sorbent with further fractionation and MS/MS analysis. C8-functionalized mesoporous magnetic microspheres are chosen as a sorbent, spatially confined with an applied magnetic field. They ensure a selective enrichment and analysis of large hydrophobic peptides (2.5-7 kDa), matching the desired mass bin of the extended bottom-up proteomic (eBUP, 3-7 kDa) approach. Within less than 35 min and without additional sample purification, SPE-GEMS/MS provided 66.5% of protein sequence coverage from 75 fmol of BSA tryptic digest. Analysis of only 33 fmol of a single monoclonal antibody, digested with secreted aspartic protease 9 (Sap9) to large peptides, yielded 80% of its sequence coverage. A more complex equimolar mixture of six antibodies (55 fmol each), submitted to Sap9 proteolysis, was also successfully processed by SPE-GEMS/MS, resulting in 50-67% of the total antibody sequence coverage. Importantly, for all antibodies, unique peptides containing complementarity determining regions were detected for both heavy and light chains, leading to a correct identification of mixture components despite their high sequence homology. Moreover, SPE-GEMS/MS microchip and chosen magnetic sorbent are cost-effective and can be produced and operated in a disposable manner. Therefore, the present technique could be potentially suitable for a high throughput sequencing of monoclonal antibodies and rapid eBUP-based structural protein analysis, especially when only a limited sample amount is available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surfactant Removal from Mesoporous ‎Silica Shell of Core-Shell Magnetic ‎Microspheres by Modified Supercritical ‎CO2‎

   In this paper, a kind of core–shell magnetic mesoporous microspheres of Fe3O4@SiO2@meso-SiO2 with high surface areawas prepared, where magnetic Fe3O4 nanospheres were used as the inner core, tetraethyl orthosilicate (TEOS) as silica source, and cetyltrimethylamonium bromide (CTAB) as pore forming agent. Methanol-enhanced s...

متن کامل

Facile and Economic Method for the Preparation of Core-Shell Magnetic Mesoporous Silica

In this work core-shell structure Fe3O4@SiO2@meso-SiO2 microsphere has been successfully prepared. An inorganic magnetic core has been coated with multi-shell structure, dense nonporous silica as an inner layer and mesoporous silica as an outer layer. The dense silica shell can enhance the stability and minimize the negative effect of acidic condi...

متن کامل

Amino Functionalized Silica Coated Fe3O4 Magnetic Nanoparticles as a Novel Adsorbent for Removal of Pb2+ and Cd2+

The present study synthesizes a novel adsorbent by coating Fe3O4 magnetic nanoparticles with amino functionalized mesoporous silica. The FTIR spectrums indicate that silica has been successfully coated on the surface of Fe3O4 and 3-aminopropyl tri methoxysilane compound have been grafted to the surface of silica-coated Fe3O4. The XRD analysis shows the presence of magnetite phase with cubic spi...

متن کامل

Peptide and protein characterization by high-rate electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry.

The analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-inject...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 2016