Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease.

نویسندگان

  • Elif Eroglu
  • Jan D'hooge
  • Lieven Herbots
  • Daisy Thijs
  • Christophe Dubois
  • Peter Sinnaeve
  • Joseph Dens
  • Johan Vanhaecke
  • Frank Rademakers
چکیده

AIMS Although dobutamine stress echocardiography (DSE) is an accepted tool for the diagnosis of coronary artery disease (CAD), it requires subsequent image acquisitions of the left ventricle (LV) in order to visualize all segments. This makes the procedure relatively time-consuming and might limit its accuracy. With the introduction of matrix array transducers, the real-time simultaneous acquisition of all LV segments has become possible using multi-plane imaging. The purpose of this study was: (i) to test the feasibility and efficiency of real-time tri-plane (RT3P) imaging during DSE, (ii) to compare the accuracy of RT3P DSE in detecting CAD using coronary angiography as the reference method. METHODS AND RESULTS Thirty-six patients suspected of CAD were prospectively enrolled. Both conventional two-dimensional (2D) and RT3P imaging were performed during a DSE protocol. Coronary angiography was performed within 24 h. Ultrasound data were acquired at each stage of the DSE. The total effective acquisition time for RT3P imaging was significantly shorter (55+/-29 vs. 137+/-63 s, P<0.001). Data yield was similar for both methods (2D: 98% vs. 3D: 97%). Overall sensitivity (93%), specificity (75%), and accuracy (89%) were identical between both methods. On a segmental level, the sensitivity, specificity, and accuracy of the RT3P and the 2D DSE were similar. CONCLUSION RT3P imaging fastens the DSE protocol without compromising the accuracy for the diagnosis of CAD. This could facilitate a more wide-spread use of DSE and therefore contributes positively to its routine clinical acceptance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Artery Spasm During Dobutamine Stress Echocardiography: A Case Report

Dobutamine stress echocardiography (DSE) has been widely used as a diagnostic and prognostic modality in the management of stress. DSE is associated with limited complications and adverse effects on the health of patients. In this case report, we described a 42-year-old female patient with dobutamine-induced coronary artery spasm with history of exertional dyspnea, which had deteriorated recent...

متن کامل

Non-invasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods.

AIMS Although two-dimensional-dobutamine stress echocardiography (2D-DSE) is useful for the diagnosis of myocardial ischaemia, it requires the acquisition of multiple cross-sections at each stage. The introduction of new real-time three-dimensional echocardiography (RT3DE) offers rapid acquisition and 3D display of the entire left ventricle (LV). The purpose was to evaluate real-time three-dime...

متن کامل

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery.

Cardiol 2004;43:257–264. 72. Jeetley P, Hickman M, Kamp O, Lang RM, Thomas JD, Vannan MA, Vanoverschelde JL, Wouw van der PA, Senior R. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Am Heart J 2004;147: 110...

متن کامل

Cardiac testing for coronary artery disease in potential kidney transplant recipients: a systematic review of test accuracy studies.

BACKGROUND Cardiovascular disease is the leading cause of death after kidney transplant. Screening for coronary artery disease is integral to pretransplant evaluation, although the relative performance of different tests is uncertain. STUDY DESIGN Systematic review of diagnostic test accuracy studies using hierarchical summary receiver operating characteristic analysis. SETTING & POPULATION...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 27 14  شماره 

صفحات  -

تاریخ انتشار 2006