Protection against cold in prehospital care: evaporative heat loss reduction by wet clothing removal or the addition of a vapor barrier--a thermal manikin study.

نویسندگان

  • Otto Henriksson
  • Peter Lundgren
  • Kalev Kuklane
  • Ingvar Holmér
  • Peter Naredi
  • Ulf Bjornstig
چکیده

INTRODUCTION In the prehospital care of a cold and wet person, early application of adequate insulation is of utmost importance to reduce cold stress, limit body core cooling, and prevent deterioration of the patient's condition. Most prehospital guidelines on protection against cold recommend the removal of wet clothing prior to insulation, and some also recommend the use of a waterproof vapor barrier to reduce evaporative heat loss. However, there is little scientific evidence of the effectiveness of these measures. OBJECTIVE Using a thermal manikin with wet clothing, this study was conducted to determine the effect of wet clothing removal or the addition of a vapor barrier on thermal insulation and evaporative heat loss using different amounts of insulation in both warm and cold ambient conditions. METHODS A thermal manikin dressed in wet clothing was set up in accordance with the European Standard for assessing requirements of sleeping bags, modified for wet heat loss determination, and the climatic chamber was set to -15 degrees Celsius (°C) for cold conditions and +10°C for warm conditions. Three different insulation ensembles, one, two or seven woollen blankets, were chosen to provide different levels of insulation. Five different test conditions were evaluated for all three levels of insulation ensembles: (1) dry underwear; (2) dry underwear with a vapor barrier; (3) wet underwear; (4) wet underwear with a vapor barrier; and (5) no underwear. Dry and wet heat loss and thermal resistance were determined from continuous monitoring of ambient air temperature, manikin surface temperature, heat flux and evaporative mass loss rate. RESULTS Independent of insulation thickness or ambient temperature, the removal of wet clothing or the addition of a vapor barrier resulted in a reduction in total heat loss of 19-42%. The absolute heat loss reduction was greater, however, and thus clinically more important in cold environments when little insulation is available. A similar reduction in total heat loss was also achieved by increasing the insulation from one to two blankets or from two to seven blankets. CONCLUSION Wet clothing removal or the addition of a vapor barrier effectively reduced evaporative heat loss and might thus be of great importance in prehospital rescue scenarios in cold environments with limited insulation available, such as in mass-casualty situations or during protracted evacuations in harsh conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Apparent latent heat of evaporation from clothing: attenuation and "heat pipe" effects.

Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34 degrees C in ambient temperatures of 10, 20, and...

متن کامل

Evaluating cold, wind, and moisture protection of different coverings for prehospital maritime transportation-a thermal manikin and human study.

INTRODUCTION Prehospital maritime transportation in northern areas sets high demands on hypothermia prevention. To prevent body cooling and hypothermia of seriously-ill or injured casualties during transportation, casualty coverings must provide adequate thermal insulation and protection against cold, wind, moisture, and water splashes. OBJECTIVE The aim of this study was to determine the the...

متن کامل

Methods of evaluating protective clothing relative to heat and cold stress: thermal manikin, biomedical modeling, and human testing.

Personal protective equipment (PPE) refers to clothing and equipment designed to protect individuals from chemical, biological, radiological, nuclear, and explosive hazards. The materials used to provide this protection may exacerbate thermal strain by limiting heat and water vapor transfer. Any new PPE must therefore be evaluated to ensure that it poses no greater thermal strain than the curre...

متن کامل

Dry and wet heat transfer through clothing dependent on the clothing properties under cold conditions.

The purpose of this study was to investigate the effect of moisture on the heat transfer through clothing in relation to the water vapour resistance, type of underwear, location of the moisture and climate. This forms part of the work performed for work package 2 of the European Union THERMPROTECT project. Thermal manikin results of dry and wet heat loss are presented from different laboratorie...

متن کامل

Evaporative cooling: effective latent heat of evaporation in relation to evaporation distance from the skin.

Calculation of evaporative heat loss is essential to heat balance calculations. Despite recognition that the value for latent heat of evaporation, used in these calculations, may not always reflect the real cooling benefit to the body, only limited quantitative data on this is available, which has found little use in recent literature. In this experiment a thermal manikin, (MTNW, Seattle, WA) w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prehospital and disaster medicine

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2012