Evaluation of four commercial immunoglobulin G (IgG)- and IgM-specific enzyme immunoassays for diagnosis of Mycoplasma pneumoniae infections.

نویسندگان

  • J Petitjean
  • A Vabret
  • S Gouarin
  • F Freymuth
چکیده

The four following commercially available enzyme immunoassays (EIAs) were assessed and compared for their performance in detecting Mycoplasma pneumoniae immunoglobulin G (IgG)- and IgM-specific antibodies Platelia EIA, ImmunoWELL M. pneumoniae ELISA IgG and IgM, ETI-MP-IgG and IgM EIAs and Biotest anti-M. pneumoniae IgG and IgM ELISA (referred to herein as EIA-Platelia, EIA-BMD, EIA-Sorin, and EIA-Biotest). Three groups of patients were investigated: 39 patients (27 children and 12 adults) with respiratory infections who tested positive by PCR for M. pneumoniae in respiratory specimens (group I; 52 serum samples), 61 healthy children and adults (group II; 61 serum samples), and 20 patients with rheumatoid factor or antinuclear antibodies, or who tested positive for antiviral IgM (group III; 20 serum samples). In group III, the IgM specificity for EIA-Platelia, EIA-BMD, EIA-Biotest, and EIA-Sorin was 100, 90, 65, and 25%, respectively. In the children from group I, the four EIAs had similar IgM sensitivities (89 to 92%); the sensitivity for IgG was greater with EIA-BMD and EIA-Biotest than with EIA-Platelia and EIA-Sorin (66 and 78% versus 55 and 52%, respectively). In adult patients from group I, 9 to 10 serum samples were positive for IgG with a concordant sensitivity of 75 to 83% between the four EIAs but a striking difference in IgM sensitivity: 16% by EIA-Platelia and EIA-BMD, 50% by EIA-Biotest, and 58% by EIA-Sorin. Discrepant and unexpected results were observed in IgM detection from control healthy patients using EIA-Sorin and EIA-Biotest, confirming the lack of specificity of these two EIAs and making them inaccurate for routine diagnosis. A good concordance of IgG seroprevalence in healthy adults was found between the four EIAs (66 to 70%), though this concordance was lower with EIA-Platelia (43%). In healthy children, EIA-BMD and EIA-Biotest gave a higher IgG seroprevalence than EIA-Sorin and EIA-Platelia (45% each for the former compared to 17 and 20%, respectively, for the latter). These results confirm that the IgM EIA serology test is a valuable tool for the early diagnosis of M. pneumoniae infections in children, as long as the EIA used is specific. In adults, the difficult interpretation of EIAs suggests that paired sera, combined with PCR detection on respiratory tract specimens collected on admission of patient, should be required for accurate diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Four Commercial IgG- and IgM-specific Enzyme Immunoassays for Detecting Mycoplasma pneumoniae Antibody: Comparison with Particle Agglutination Assay

Diagnosis of Mycoplasma pneumoniae infection is important due to its variable clinical manifestations and absence of response to beta-lactams. Introduction of enzyme immunoassays (EIAs) for serologic diagnosis of M. pneumoniae has made it possible to separate the analyses of specific IgG and IgM antibodies. We compared four different commercial EIAs, ImmunoWELL IgG, IgM (GenBio), Medac IgG, IgA...

متن کامل

Analysis of complement fixation and commercial enzyme immunoassays for detection of antibodies to Mycoplasma pneumoniae in human serum.

The Meridian ImmunoCard (IC), GenBio ImmunoWELL-IgM, and Remel EIA commercial antibody tests are qualitative enzyme immunoassays that detect antibodies to Mycoplasma pneumoniae in serum. These tests were compared to an M. pneumoniae complement fixation (CF) assay, which uses a commercially available antigen component. The Meridian IC and the ImmunoWELL-IgM detect immunoglobulin M (IgM) only; th...

متن کامل

Diagnosis of Mycoplasma pneumoniae pneumonia in children.

We evaluated a commercial immunoglobulin M (IgM)-capture immunoassay for the detection of Mycoplasma pneumoniae infections in 278 pediatric patients with community-acquired, radiographically defined pneumonia. Acute- and convalescent-phase serum samples were collected from all patients and were tested for M. pneumoniae-specific IgM and IgG antibodies by Platelia enzyme immunoassays (Sanofi Diag...

متن کامل

Evaluation of 12 commercial tests and the complement fixation test for Mycoplasma pneumoniae-specific immunoglobulin G (IgG) and IgM antibodies, with PCR used as the "gold standard".

Serology and nucleic acid amplification are the main diagnostic tools for the diagnosis of Mycoplasma pneumoniae infection. Since no reference standard is generally accepted, serologic assays for M. pneumoniae have not been evaluated on a broad scale. In this study, 12 commercially available serologic assays (for immunoglobulin G [IgG] and IgM) and the complement fixation test (CFT) were evalua...

متن کامل

Asthmatic children have increased specific anti-Mycoplasma pneumoniae IgM but not IgG or IgE-values independent of history of respiratory tract infection.

BACKGROUND Bronchial asthma is exacerbated by Mycoplasma pneumoniae-induced upper respiratory tract infections (URTIs) in children. Specific IgM and IgG isotypes are involved in the immune response to M. pneumoniae, but little is known about the role of specific IgE antibodies against M. pneumoniae in asthma. OBJECTIVE To investigate the role of IgM-, IgG- and IgE-specific antibody responses ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pathologie-biologie

دوره 50 9  شماره 

صفحات  -

تاریخ انتشار 2002