A Case of Increasing the Overload Capability of Transformer

نویسندگان

  • Mohamed ZOUITI
  • Patrick RAISON
  • Andre ERDMANN
چکیده

The following paper describes a case of increasing the overload capability of a 70 MVA power transformer up to 100 MVA. The realization of this project was done in close collaboration between the utility and the manufacturer. Primarily, EDF R&D performed thermohydraulic calculations that confirm the feasibility of this project. Secondly, the manufacturer confirms the ability of the transformer to withstand the over-flux by means of electromagnetic calculations. Finally, ERDF decide to test the solution in factory and then on site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technological capabilities assessment in the transformer industry: A case-study of investigating technological capabilities in Iran-Transfo Company

In this research is presented a method for technological capabilities assessment in a company in transformer industry. Used and discussed criteria in this technique are merely developed to assess technological capabilities in transformer industry. Based on literature, technological capabilities in transformer industry are divided into three main categories: production capability, development an...

متن کامل

Overload Control in Smart Transformer-Fed Grid

Renewable energy resources and new loads—such as electric vehicles—challenge grid management. Among several scenarios, the smart transformer represents a solution for simultaneously managing lowand medium-voltage grids, providing ancillary services to the distribution grid. However, unlike conventional transformers, the smart transformer has a very limited overload capability, because the junct...

متن کامل

Multi-objective Based Optimization Using Tap Setting Transformer, DG and Capacitor Placement in Distribution Networks

In this article, a multi-objective function for placement of Distributed Generation (DG) and capacitors with thetap setting of Under Load Tap Changer (ULTC) Transformer is introduced. Most of the recent articles have paidless attention to DG, capacitor placement and ULTC effects in the distribution network simultaneously. Insimulations, a comparison between different modes was carried out with,...

متن کامل

Reliability Analysis and Overload Capability Assessment of Oil-Immersed Power Transformers

Smart grids have been constructed so as to guarantee the security and stability of the power grid in recent years. Power transformers are a most vital component in the complicated smart grid network. Any transformer failure can cause damage of the whole power system, within which the failures caused by overloading cannot be ignored. This research gives a new insight into overload capability ass...

متن کامل

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015