Comparison of morphologic features of clear corneal incisions created with a femtosecond laser or a keratome.
نویسندگان
چکیده
PURPOSE To compare the morphology of clear corneal incisions (CCIs) created with a femtosecond laser (Catalys) or a keratome (2.65 mm steel) during phacoemulsification using anterior segment optical coherence tomography (AS-OCT) and analyze the intended versus the achieved morphologic characteristics of femtosecond laser-generated CCIs. SETTING Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA. DESIGN Comparative case series. METHODS Eyes with femtosecond CCIs and age-matched eyes with the keratome CCIs underwent AS-OCT of the incisions 1 month after phacoemulsification. ImageJ software was used to evaluate AS-OCT images for CCI length, endothelial gaping, endothelial misalignment, and Descemet membrane detachment. RESULTS In the femtosecond group (20 eyes) and keratome group (16 eyes), the mean values were CCI length, 1.99 mm±0.07 (SEM) versus 2.04±0.23 mm (P=.39); endothelial gaping, 0.14±0.03 mm versus 0.19±0.09 mm (P=.03); endothelial misalignment, 0.04±0.03 mm versus 0.08±0.06 mm (P=.022). No eye in the femtosecond group and 3 eyes in the keratome group had a Descemet membrane detachment (P=.04). Six femtosecond eyes and 11 keratome eyes had posterior wound retraction (P=.02). The mean CCI length was 94.9% of the intended 2.1 mm, the posterior plane depth was 93.3% of the intended 70%, and the posterior side-cut angle was 91.7% of the intended 45 degrees. CONCLUSION Femtosecond laser-generated CCIs had significantly lower endothelial gaping, endothelial misalignment, Descemet membrane detachment, and posterior wound retraction than keratome-created CCIs and were within 10% of the intended length, depth, and angle measurements. FINANCIAL DISCLOSURE Neither author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Comparing consistency of clear corneal incisions using a traditional diamond keratome and a newly designed diamond keratome
PURPOSE To compare the consistency of incision architecture utilizing a traditional diamond keratome and a newly designed diamond keratome. METHODS We used a traditional diamond keratome and newly designed diamond keratome to create clear corneal incisions in human cadaveric donor eyes. Three surgeons with varying levels of experience made 30 incisions with each keratome; and the wound archit...
متن کاملComplicated flap creation with femtosecond laser after radial keratotomy.
PURPOSE To report a case of laser in situ keratomileusis (LASIK) that used the Intralase femtosecond laser 14 years after radial keratotomy (RK) for residual myopic astigmatism. METHODS A 39 year-old male patient had undergone a bilateral RK operation for myopic correction. The manifest refraction was -1.25 -3.00 x 175 D, with uncorrected visual acuity (UCVA) of 20/50 and best-corrected visua...
متن کاملEvaluation of femtosecond laser clear corneal incision: an experimental study.
PURPOSE To evaluate the changes of corneal topography following femtosecond laser and manual clear corneal incision (CCI). METHODS Inflation testing was performed in 14 human eye globes to evaluate the topographic response of the cornea to CCIs. In seven samples (femtosecond laser group), a 2.75-mm three-plane CCI was created using the iFS femtosecond laser (Abbott Medical Optics, Inc., Santa...
متن کاملFemtosecond laser versus mechanical microkeratome: a retrospective comparison of visual outcomes at 3 months.
PURPOSE To compare the visual outcomes of LASIK procedures in which flaps were created with a femtosecond laser (IntraLase FS 60Hz, Abbott Medical Optics [AMO]) to procedures in which flaps were created with a mechanical microkeratome (Moria Evo3 One Use-Plus, Moria SA). METHODS A retrospective analysis was performed on 2000 eyes treated in 2008 for low myopia and astigmatism (sphere < -3.00 ...
متن کاملIntegrity of Intrastromal Arcuate Keratotomies Performed by Femtosecond Laser.
To the Editor: Femtosecond laser platforms used for cataract surgery are integrated with anterior-segment optical coherence tomography (AS-OCT), allowing for real-time imaging and measurement of the cornea, possibly leading to more precise arcuate keratotomies.1 The femtosecond laser permits creation of either anterior penetrating incisions or intrastromal incisions. The advantages of intrastro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2014