Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study.

نویسندگان

  • Emma L Bates
  • Christopher M Bragg
  • Jim M Wild
  • Matthew Q F Hatton
  • Rob H Ireland
چکیده

BACKGROUND AND PURPOSE To investigate the incorporation of data from single-photon emission computed tomography (SPECT) or hyperpolarized helium-3 magnetic resonance imaging ((3)He-MRI) into intensity-modulated radiotherapy (IMRT) planning for non-small cell lung cancer (NSCLC). MATERIAL AND METHODS Seven scenarios were simulated that represent cases of NSCLC with significant functional lung defects. Two independent IMRT plans were produced for each scenario; one to minimise total lung volume receiving >or=20Gy (V(20)), and the other to minimise only the functional lung volume receiving >or=20Gy (FV(20)). Dose-volume characteristics and a plan quality index related to planning target volume coverage by the 95% isodose (V(PTV95)/FV(20)) were compared between anatomical and functional plans using the Wilcoxon signed ranks test. RESULTS Compared to anatomical IMRT plans, functional planning reduced FV(20) (median 2.7%, range 0.6-3.5%, p=0.02), and total lung V(20) (median 1.5%, 0.5-2.7%, p=0.02), with a small reduction in mean functional lung dose (median 0.4Gy, 0-0.7Gy, p=0.03). There were no significant differences in target volume coverage or organ-at-risk doses. Plan quality index was improved for functional plans (median increase 1.4, range 0-11.8, p=0.02). CONCLUSIONS Statistically significant reductions in FV(20), V(20) and mean functional lung dose are possible when IMRT planning is supplemented by functional information derived from SPECT or (3)He-MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Concurrent chemoradiotherapy in locally advanced non-small cell lung cancer: a retrospective analysis of the correlation between radiotherapy-related factors and tumor response

Background: To determine which radiotherapy parameters are associated with the tumor response of locally advanced non-small cell lung cancer (NSCLC) patients undergoing concurrent chemoradiotherapy. Materials and Methods: Thirty one patients with IIIA/IIIB NSCLC underwent chemoradiotherapy with a median dose of 63 Gy. On our actual treatments, we made radiotherapy planning to cover the planning...

متن کامل

Comparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer

Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...

متن کامل

A Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.

 Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2009