Correlative Array Tomography – from 2D towards 3D
نویسندگان
چکیده
Correlative microscopy combines information from light and electron microscopy (LM and EM) into one comprehensive dataset. The “Shuttle & Find” interface from Zeiss was the first easy to use solution for imaging one and the same sample region in different microscopes, i.e. from widefield or confocal LMs to environmental or field emission SEMs (FE-SEM). However, Shuttle & Find is limited to 2D applications. Correlative Array Tomography is a novel 3D approach and works with ultrathin serial sections that can be fluorescently stained for LM investigations and transferred into the SEM afterwards. In contrast to serial block face methods (i.e. 3View or focused ion beam SEM) Correlative Array Tomography is a non-destructive method that allows multiple investigations of the same sample and even multiple successive fluorescent staining procedures [1]. This approach also improves z-resolution in LM since that is now governed by the thickness of the serial sections.
منابع مشابه
Correlative Tomography
Increasingly researchers are looking to bring together perspectives across multiple scales, or to combine insights from different techniques, for the same region of interest. To this end, correlative microscopy has already yielded substantial new insights in two dimensions (2D). Here we develop correlative tomography where the correlative task is somewhat more challenging because the volume of ...
متن کاملCorrelative Nanoscale 3D Imaging of Structure and Composition in Extended Objects
Structure and composition at the nanoscale determine the behavior of biological systems and engineered materials. The drive to understand and control this behavior has placed strong demands on developing methods for high resolution imaging. In general, the improvement of three-dimensional (3D) resolution is accomplished by tightening constraints: reduced manageable specimen sizes, decreasing an...
متن کاملCorrelative Light and Electron Microscopy – on the Way from 2D Towards 3D
The next step will be to address correlative 3D applications. To achieve this, it is necessary to exactly define volumes of interest (VOI) in the data of the first microscope. Further, the precise relocation of the identical VOI in the second microscope is essential as well as the registration of the 3D object in all spatial directions. However, the correlation of 3-dimensional data from differ...
متن کاملMRI Volume Fusion Based on 3D Shearlet Decompositions
Nowadays many MRI scans can give 3D volume data with different contrasts, but the observers may want to view various contrasts in the same 3D volume. The conventional 2D medical fusion methods can only fuse the 3D volume data layer by layer, which may lead to the loss of interframe correlative information. In this paper, a novel 3D medical volume fusion method based on 3D band limited shearlet ...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...