In vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materials.

نویسندگان

  • Rafael Ratto de Moraes
  • Daiane dos Santos Ribeiro
  • Mirian Margarete Klumb
  • William Cunha Brandt
  • Lourenço Correr-Sobrinho
  • Márcia Bueno
چکیده

This study evaluated weight loss and surface roughening after toothbrushing of different resin composites: one packable (Solitaire 2, Heraeus Kulzer), one microhybrid (Charisma, Heraeus Kulzer), one nanohybrid (Simile, Pentron) and one microfilled (Durafill VS, Heraeus Kulzer). Cylindrical specimens (n = 20) were prepared. Half of the samples were submitted to 60,000 strokes, at 4 Hz, with a dentifrice-water slurry. Control samples (n = 10) remained stored at 37 degrees C. Pre- and post-abrasion parameters for weight (mg) and surface roughness (Ra, microm) were determined on an analytical balance and a surface profilometer. Data were separately submitted to Repeated Measures ANOVA and Tukey's test (a = 0.05). Percentages of weight loss were analyzed by ANOVA and Tukey's test (a = 0.05). The relationship between both evaluations was assessed by Pearson's test (a = 0.05). The means (%) for weight loss (standard deviation) were 0.65(0.2), 0.93(0.2), 1.25(0.6) and 1.25(0.4) for Simile, Durafill, Charisma and Solitaire, respectively. Baseline roughness means ranged from 0.065(0.01), 0.071(0.01), 0.066(0.02) and 0.074(0.01) for Simile, Durafill, Charisma and Solitaire, respectively, to 0.105(0.04), 0.117(0.03), 0.161(0.03) and 0.214(0.07) after testing. The composites with larger fillers presented higher weight loss and roughening than the finer materials (p < 0.05). For both evaluations, control specimens showed no significant alteration. No significant relationship between loss of weight and roughness alteration was detected (r = 0.322, p = 0.429).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of re-bonding using surface sealant or adhesive system on microleakage of class V resin composite restorations

BACKGROUND Microleakage is still one of the defects of resin composites that can lead to treatment failure; and re-bonding technique is one of the effective ways to reduce it. This study evaluated the effect of re-bonding with a surface sealant or a dentin adhesive on microleakage in class V microhybrid, nanohybrid, and packable composite restorations. MATERIALS AND METHODS In this in vitro s...

متن کامل

Evaluation of the roughness and mass loss of the flowable composites after simulated toothbrushing abrasion.

The purpose of this study was to measure mass loss and surface roughness changes of different brands of flowable resin composites after a simulated toothbrushing test. The null hypotheses were that there would be no differences in mass loss and no significant changes in surface roughness after this test and that there would be no correlation between the two variables. The tested materials were ...

متن کامل

Resistance of nanofill and nanohybrid resin composites to toothbrush abrasion with calcium carbonate slurry.

The aim of this study was to investigate the wear of four nanofilled resin composites using simulated toothbrushing for 50,000 cycles with calcium carbonate slurry. The depth of abrasion and roughness (Ra) were measured after each 10,000 brushing cycle. The surface texture of the worn samples was examined by SEM.The wear depths of the nanofill Filtek Supreme XT (FIL), the nanohybrides Grandio (...

متن کامل

Effects of different polishing methods on color stability of resin composites after accelerated aging.

The purpose of this study was to evaluate the effect of polishing procedures on the color stability of different types of composites after aging. Forty disk-shaped specimens (Ø10×2 mm) were prepared for each composite resin type (an ormocer, a packable, a nanohybrid, and a microhybrid) for a total of 160 specimens. Each composite group was divided into four subgroups according to polishing meth...

متن کامل

In vitro wear of microfilled and visible light-cured composites.

Wear of microfilled composites, a visible light-cured composite, and a conventional composite were characterized by two-body abrasion and single-pass sliding. There were differences in abrasion rates among the materials. Tangential forces, wear track widths, and surface failure modes were different among materials. Wear characteristics are combinations of these properties.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2008