Clinical results of treatment using a modified K-wire tension band versus a cannulated screw tension band in transverse patella fractures
نویسندگان
چکیده
It was a retrospective case-control study. The aim of this study was to explore the clinical efficacy and complication of treatment using a modified Kirschner wire tension band (MKTB) or a cannulated screw tension band (CSTB) in transverse patellar fractures.In total, 55 patients with transverse patellar fractures were retrospectively reviewed and divided into 2 groups according to the surgical technique: 29 patients were in the MKTB group and 26 patients in the CSTB group. B[Latin Small Letter o with Caron]stman's clinical grading scale, including range of movement (ROM), pain, ability to work, atrophy of quadriceps femoris, assistance in walking, effusion, giving way, and stair-climbing, was used to evaluate the clinical results. Complications including painful hardware, implant loosening or breakage, and bone nonunion were also assessed.Both groups were evaluated at the final follow-up before removing implant in the MKTB group. The B[Latin Small Letter o with Caron]stman's score of ROM, pain, atrophy of quadriceps femoris, and effusion were all higher in the CSTB group than in the MKTB group (P < 0.05). Twelve patients in the MKTB group underwent implant removal, and the score of ROM, pain, and effusion were higher than before removing implant (P < 0.05), but there was no difference compared to the CSTB group (P > 0.05). Seventeen patients achieved excellent results, 9 had good results, and 3 reported fair results in the MKTB group; the CSTB group had excellent results in 22 patients and good results in 4 patients, showing a significant difference in the excellent rate between the 2 groups (P = 0.021). Total B[Latin Small Letter o with Caron]stman scores in the MKTB and CSTB groups (26.96 ± 4.47 and 29.42 ± 1.47, respectively) were significantly different (P = 0.01). Total scores in the MKTB group after removing implant were higher than those before removing implant (P = 0.001), and similar to those in the CSTB group (P = 0.224). Eleven patients in the MKTB group reported painful hardware, including 4 cases of implant loosening.CSTB achieves better clinical results than MKTB, meanwhile avoiding the problems of painful hardware and implant loosening. Functional limitation caused by hardware pain was commonly seen in the MKTB group, and removing implant after fracture healing improved knee function.
منابع مشابه
Cannulated Screw and Cable are Superior to Modified Tension Band in the Treatment of Transverse Patella Fractures
BACKGROUND Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. QUESTIONS/PURPOSES We conducted a retrospective comparison of the modified tension band technique and the t...
متن کاملComparison of a minimally invasive technique with open tension band wiring for displaced transverse patellar fractures.
BACKGROUND Open reduction and internal fixation with tension band wire is the standard treatment for displaced transverse patellar fractures. Recently, some minimally invasive techniques have been proposed as possible alternative methods. This retrospective study compared a newly reported percutaneous osteosynthesis with conventional open method for the treatment of displaced transverse patella...
متن کاملInternal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring
Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1) or transverse with mildly comminuted (AO34-C2) patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the ...
متن کاملComparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
BACKGROUND K wire fixation with tension band wiring has conventionally been used for the open reduction and internal fixation of the patella. However, it suffers from distinct disadvantages such as implant irritation, need for open reduction, incidence of palpable implants, and need for subsequent implant removal. A smaller incision with percutaneous fixation may be an alternative to this estab...
متن کاملPercutaneous Cannulated Screws with Tension Band Wiring Technique in Patella Fractures
INTRODUCTION Most patellar fractures are transverse involving the central third. Open reduction and stabilization of transverse patellar fractures is indicated if there is more than 2-3 mm of fragment separation and/or articular incongruity. SURGICAL TECHNIQUE This study describes a percutaneous 2 cannulated screws and modified tension band wiring technique to treat transverse patellar fractu...
متن کامل