Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

نویسندگان

  • N Fischer
  • L Pinggera
  • V Weichbold
  • D Dejaco
  • J Schmutzhard
  • G Widmann
چکیده

BACKGROUND AND PURPOSE Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. MATERIALS AND METHODS This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. RESULTS In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. CONCLUSIONS The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography as an orientation guide in cochlear implant surgery?

CONCLUSION With optical coherence tomography (OCT) it is basically possible to reveal parts of the cochlear morphology without opening its enveloping membranes. Thus, it may serve as a helpful guide for the surgeon to localize the scala tympani precisely before opening the fluid-filled inner ear to insert the electrode array. OBJECTIVE To improve anatomical orientation in cochlear implant sur...

متن کامل

Optical coherence tomography as a guide for cochlear implant surgery?

Optical coherence tomography as a guide for cochlear implant surgery? To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal...

متن کامل

Comparison of three-dimensional visualization techniques for depicting the scala vestibuli and scala tympani of the cochlea by using high-resolution MR imaging.

BACKGROUND AND PURPOSE Cochlear implantation requires introduction of a stimulating electrode array into the scala vestibuli or scala tympani. Although these structures can be separately identified on many high-resolution scans, it is often difficult to ascertain whether these channels are patent throughout their length. The aim of this study was to determine whether an optimized combination of...

متن کامل

An overview of cochlear implant electrode array designs

Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode arra...

متن کامل

Semiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation

A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy tar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2015