Effective lubrication performance of metal-on-metal hip implants only requires optimum conformity within the main loaded area, while it is advantageous to increase the clearance in the equatorial region. Such a varying clearance can be achieved by using non-spherical bearing surfaces for either acetabular or femoral components. An elastohydrodynamic lubrication model of a novel metal-on-metal hip prosthesis using a non-spherical femoral bearing surface against a spherical cup was solved under loading and motion conditions specified by ISO standard. A full numerical methodology of considering the geometric variation in the rotating non-spherical head in elastohydrodynamic lubrication solution was presented, which is applicable to all non-spherical head designs. The lubrication performance of a hip prosthesis using a specific non-spherical femoral head, Alpharabola, was analysed and compared with those of spherical bearing surfaces and a non-spherical Alpharabola cup investigated in previous studies. The sensitivity of the lubrication performance to the anteversion angle of the Alpharabola head was also investigated. Results showed that the non-spherical head introduced a large squeeze-film action and also led to a large variation in clearance within the loaded area. With the same equatorial clearance, the lubrication performance of the metal-on-metal hip prosthesis using an Alpharabola head was better than that of the conventional spherical bearings but worse than that of the metal-on-metal hip prosthesis using an Alpharabola cup. The reduction in the lubrication performance caused by the initial anteversion angle of the non-spherical head was small, compared with the improvement resulted from the non-spherical geometry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.

Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the r...

متن کامل

Predictive wear modeling of the articulating metal-on-metal hip replacements.

The lubrication regime in which artificial hip joints operate adds complexity to the prediction of wear, as the joint operates in both the full fluid film regime-specifically the elastohydrodynamic lubrication (EHL) regime-and the mixed or boundary lubrication regimes, where contact between the bearing surfaces results in wear. In this work, a wear model is developed which considers lubrication...

متن کامل

Elasto-hydrodynamic Lubrication Modelling of Spherical Metal-on-metal Aftificial Hip Joints

A full numerical methodology was developed for the elasto-hydrodynamic lubrication analysis of hip joint implants for the lubrication problem in spherical and conformal contacts. Typical results of a metal-on-metal hip implant were obtained to illustrate the applicability of the numerical methodology developed in the present study. INTRODUCTION The important effect of lubrication on long-term s...

متن کامل

An Investigation of the Fatigue Induced Failure Modes of Fiber/Elastomer Composites as Bearing Surfaces in Total Hip Joint Prosthesis

It is proposed to use elastomeric composites as artificial joint bearing surfaces to increase their fluid film lubrication and therefore reduce the number of failures which have been attributed to wear mechanisms related to frictional forces. The fluid generated between the surfaces supports part of the load and prevents direct contact of the bearing surfaces. In order to obtain optimum elastoh...

متن کامل

The Bateman bipolar femoral head replacement. A fluoroscopic study of movement over a four-year period.

The purpose of this study was to establish if the Bateman prosthesis functions as a bipolar device moving primarily at the inner metal-on-polyethylene bearing as originally proposed, or as a unipolar hemiarthroplasty moving at the outer metal-on-cartilage surface as has recently been suggested. One hundred hips were examined at one year follow-up; 78 were examined again at two to four years. Th...