Study of the Inner Structure of a Damaged Control Rod by Neutron and X-Ray Radiography and Discrete Tomography

نویسندگان

  • M. BALASKÓ
  • E. SVÁB
  • Z. KISS
  • A. TANÁCS
  • A. NAGY
  • A. KUBA
چکیده

A control rod K5 of the 10 MW Budapest Research Reactor was damaged in 2004. We have applied both neutron and X-ray radiography to study the distribution of the residual material in the damaged K5. X-ray radiography visualized the main distribution of the residual materials, like different kinds of B4C and water, and the frozen gas bubbles, while neutron radiography displayed the fine structure of the congealed B4C. The 3D reconstruction of the most interesting parts of K5 has been done by discrete tomography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL

 ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008