Stability of a Ag/AgCl reference electrode equipped with an ionic liquid salt bridge composed of 1-methyl-3-octylimidazolium bis(trifluoromethanesulfonyl)-amide in potentiometry of pH standard buffers.

نویسندگان

  • Manabu Shibata
  • Mikito Yamanuki
  • Yasukazu Iwamoto
  • Satoshi Nomura
  • Takashi Kakiuchi
چکیده

The stability of a Ag/AgCl reference electrode equipped with a gelled ionic liquid, 1-methyl-3-octylimidazolium bis(trifluoromethanesulfonyl)amide (C(8)mimC(1)C(1)N), as a salt bridge, was examined in the potentiometry of pH standard solutions. The variation in the liquid junction potential (LJP) of the ionic liquid (IL)-type reference electrode, measured with respect to a double junction-type KCl reference electrode, was within 1 mV when one standard solution was replaced by another, except for the phthalate standard. The time course of the potential of the IL-type reference electrode showed a standard deviation of ±0.3 mV in all buffer solutions. The reproducible deviation of the potential of the IL-type reference electrode in the phthalate pH standard amounted to 5 mV. The deviation is due to the partition of the hydrogen phthalate in the C(8)mimC(1)C(1)N, influencing the phase boundary potential (PBP) across the interface between C(8)mimC(1)C(1)N and the phthalate standard. If a citrate standard is used instead of the phthalate buffer, the IL salt bridge works satisfactorily as a salt bridge for a reference electrode suitable for potentiometoric pH measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraction of gallium(III) from hydrochloric acid solutions by trioctylammonium-based mixed ionic liquids.

The extractabilities of aluminium(III), gallium(III), and indium(III) from hydrochloric acid solutions were investigated using a mixture of two protic ionic liquids, trioctylammonium bis(trifluoromethanesulfonyl)amide ([TOAH][NTf(2)]) and trioctylammonium nitrate ([TOAH][NO(3)]). At a HCl concentration of 4 mol L(-1) or more, gallium(III) was nearly quantitatively extracted and the extractabil...

متن کامل

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

The Effect on Performance of Fabrication Parameter Variations of Thick-Film Screen Printed Silver/Silver Chloride Potentiometric Reference Electrodes

Thick-film screen printed silver-silver chloride (Ag/AgCl) reference electrodes have been fabricated and investigated as an alternative to liquid electrolyte Ag/AgCl reference electrodes. The performance of the electrodes was examined with variations of the potassium chloride (KCl) concentration in the final (top) layer of the electrode. Also, different types of binder (glass and polymer) were ...

متن کامل

Determination and Modeling of Activity Coefficients of Sodium Chloride in (Glycerol + Water) Mixtures Based on Potentiometric Measurements

In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...

متن کامل

A Microfluidic pH Measurement Device with a Flowing Liquid Junction

The pH values of aqueous solutions are conventionally measured with pH-sensitive electrodes such as glass electrodes or ion-sensitive field-effect transistors (ISFETs) used in conjunction with Ag/AgCl reference electrodes and KCl solutions. The speed of pH measurement with these systems can be deficient, however, as the glass electrode responds slowly during measurements of sample solutions wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 26 11  شماره 

صفحات  -

تاریخ انتشار 2010