Preanalytical conditions of point-of-care testing in the intensive care unit are decisive for analysis reliability

نویسندگان

  • Adrien Auvet
  • Fabien Espitalier
  • Leslie Grammatico-Guillon
  • Mai-Anh Nay
  • Djilali Elaroussi
  • Marc Laffon
  • Christian R. Andres
  • Annick Legras
  • Stephan Ehrmann
  • Pierre-François Dequin
  • Chantal Gendrot
  • Antoine Guillon
چکیده

BACKGROUND Point-of-care testing (POCT) systems enable a wide range of tests to be rapidly performed at the bedside and have attracted increasing interest in the intensive care unit (ICU). However, previous studies comparing the concordance of POCT with central laboratory testing have reported divergent findings. Most reported studies on POCT reliability have focused on analyzer performance rather than the preanalytical phase. The aim of this study was to assess the reliability of results provided by point-of-care analyzers according to the organization of the care units and the preanalytical process. METHODS In three adult critical care units, 491 paired blood samples were analyzed for hemoglobin, potassium, and sodium concentrations by blood gas analyzers (identical reference) and the central laboratory. The clinical significance of agreement was assessed using Bland-Altman plots. A quality improvement program was then implemented to improve the preanalytical POCT process for one ICU where there was poor agreement. A second comparison was performed on 278 paired blood samples in this unit. RESULTS Biases were clinically nonsignificant for potassium and sodium concentrations for all tested critical care units, relative to the reference method. However, biases [limits of agreements] for hemoglobin analyses were clearly affected by the preanalytical process: -3 [-6; 1] g/L in the operating room, -5 [-28; 17] g/L in a 10-bed ICU, and -19 [-64; 27] g/L in a 37-bed ICU. The quality approach was implemented in the 37-bed ICU and led to corrective actions that: (1) reduced the time for the POCT preanalytical phase; (2) implemented a checklist to validate the preanalytical conditions; (3) used technical innovations. The improvement of the preanalytical process resulted in a substantial decrease of the bias for hemoglobin concentration measurements: -3 [-10; 5] g/L in the 37-bed ICU. CONCLUSION We clearly demonstrate that an identical analyzer can provide results of varying quality depending on the local constraints of the ICUs. We demonstrate that quality management focused on the preanalytical process and performed by the partners involved in the POCT can overcome these issues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of psychometric assessment questionnaire to determine the causes of discomfort among patients admitted to the intensive care unit

Background: Particular circumstances in the intensive care unit have led the patients to experience significant levels of pain and discomfort. On the other hand, these patients cannot express their discomfort due to several reasons. Aim: to develop the causes of discomfort in the intensive care units. Methods: In order for assessing the causes of discomfort, the initial questionnaire was extrac...

متن کامل

Clinical Predictors of Intensive Care Unit Admission for Asthmatic Children

IntroductionChildren with severe asthma attack are a challenging group of patients who could be difficult to treat and leading to significant morbidity and mortality. Asthma attack severity is qualitatively estimated as mild, moderate and severe attacks and respiratory failure based on conditions such as respiration status, feeling of dyspnea, and the degree of unconsciousness. part of which ar...

متن کامل

Evaluation of Human Errors among Nurses Using Predictive Analysis of Cognitive Errors and Human Event Analysis Techniques: Case study of the Specific Responsibilities of the Cardiac Intensive Care Unit

Introduction: Considering the accreditation of international standards of hospitals and the necessity to improve the safety and quality of patients’ care, this study aimed at evaluating reliability among nurses using predictive analysis of cognitive errors and human event analysis techniques. Material and Methods: The analysis of nurses̓ tasks was done by HTA method. Then, the types of errors a...

متن کامل

Nurses' Experiences of Palliative Care in the Neonatal Intensive Care Unit

Background & purpose: Despite recent advances in infant care technology, a number of infants are at risk in infancy period and need to palliative care. Nurses are responsible for the palliative care of the infants and the families. Therefore, the present study was conducted to explain the Nurses' Experiences of Palliative Care in the Neonatal Intensive Care Unit. Materials and Methods: This st...

متن کامل

Determination of Technical Efficiency of Intensive Care Units in Hospitals Afilliated to Kerman University of Medical Sciences by Stochastic Frontier Analysis in 2008

Background & Aims: Hospitals are the most important centers that provide health services in the country. They have to use scientific and efficient management at all levels for promoting health. Intensive care units (ICU) are one of the most sensitive parts of the hospitals; therefore, paying attention to its efficiency is of particular importance. The purpose of this paper was to estimate the t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016