Results of photon absorbed-dose measurements using the AAPM TG-21 protocol for accelerating potentials up to 26 MV.

نویسندگان

  • J D Hazle
  • T H Kirby
  • R J Gastorf
  • W F Hanson
چکیده

The AAPM Task Group 21 protocol for the calibration of high-energy photon and electron beams was produced to accomplish essentially two goals: (1) incorporate the latest physical data available for calculating absorbed dose from ionization measurements and (2) to eliminate inconsistencies in absorbed dose measurements made with various ion chamber and phantom combinations. The ability of the protocol was assessed to consistently determine x-ray absorbed dose from measurements made with four Farmer-type chambers and one parallel-plate chamber in water, polystyrene, and acrylic phantoms. The measurements were performed using seven high-energy x-ray beams from 60Co to 26-MV nominal accelerating potential. The absorbed dose to water calculated from measurements made with the various chamber and phantom combinations were found to be consistent. The doses calculated for the two most common phantom materials, water and polystyrene, were found to be in excellent agreement. This resolved a 1.6% discrepancy in the absorbed dose determined from the two phantoms using the SCRAD protocol. The doses for acrylic phantoms were found to be approximately 1.2%, low for nominal accelerating potentials less than 8.8 MV. For accelerating potentials of 8.8 MV or greater the agreement was considerably better. The mean dose determined for the parallel-plate chamber from measurements in polystyrene was found to be within 0.7% of the mean dose determined using Farmer-type ion chambers in all phantom materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

متن کامل

Comparison of AAPM Addendum to TG‐51, IAEA TRS‐398, and JSMP 12: Calibration of photon beams in water

The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recom...

متن کامل

Comparison between TG‐51 and TG‐21: Calibration of photon and electron beams in water using cylindrical chambers

A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosime...

متن کامل

The effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

متن کامل

Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.

Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS-398 and AAPM TG-51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 1991