Impact of Laboratory Practice Changes on the Diagnosis of Tuberculosis with the Introduction of Xpert MTB/RIF in Kiribati.

نویسندگان

  • Alfred Tonganibeia
  • Anthony D Harries
  • Onofre Edwin A Merilles
  • Tekaibeti Tarataake
  • Teatao Tiira
  • Takeieta Kienene
چکیده

The Republic of Kiribati, Central Pacific, has the largest tuberculosis epidemic in the region. There is a national tuberculosis control program, which has used smear microscopy for acid-fast bacilli as the main diagnostic tool for many years. In 2015, an Xpert MTB/RIF machine was procured and became functional within the tuberculosis hospital. The aim of this cross-sectional study, using routinely collected data, was to determine the effects of introducing Xpert MTB/RIF on laboratory smear microscopy practices and the pattern of registered tuberculosis cases. Between February 2015 and January 2016, there were 220 Xpert MTB/RIF assays performed with 6.4% errors and 15% detection of Mycobacterium tuberculosis: one patient showed rifampicin-resistance. One year before and after introducing Xpert MTB/RIF, the number of presumptive tuberculosis patients increased by 9% from 2,138 to 2,322. There were no changes in demographic characteristics, smear-positive results, or acid-fast bacilli grade between the two periods. The number of specimens cultured for Mycobacterium tuberculosis significantly declined from 638 to zero, with 76 positive MTB cultures before and none after introducing Xpert MTB/RIF. There was a significant change in the profile of registered tuberculosis cases with more children (34% versus 21%) and fewer bacteriologically-confirmed cases (29% versus 43%) - P < .001. Since the deployment of Xpert MTB/RIF in Kiribati, there have been a small number of assays performed and this has been associated with no adverse effects on smear microscopy, a stoppage in mycobacterial cultures, and a change in the types and categories of diagnosed tuberculosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of introduction of Xpert MTB/RIF test on tuberculosis (TB) diagnosis in a city with high TB incidence in Brazil

BACKGROUND Xpert MTB/RIF is increasingly used in many countries as the initial diagnostic test for tuberculosis (TB). Few studies have evaluated the effect of Xpert on TB diagnosis under programmatic conditions in Brazil. The aim of the present study was to evaluate the impact of introduction of Xpert MTB/RIF on TB diagnosis in a city with high TB incidence in Brazil. METHODS We included pati...

متن کامل

The Use of Xpert MTB/Rif for Active Case Finding among TB Contacts in North West Province, South Africa

Introduction. Tuberculosis is a major cause of morbidity and mortality especially in high HIV burden settings. Active case finding is one strategy to potentially reduce TB disease burden. Xpert MTB/Rif has recently been recommended for diagnosis of TB. Methods. Pragmatic randomized trial to compare diagnosis rate and turnaround time for laboratory testing for Xpert MTB/Rif with TB microscopy an...

متن کامل

Population-Level Impact of Same-Day Microscopy and Xpert MTB/RIF for Tuberculosis Diagnosis in Africa

OBJECTIVE To compare the population-level impact of two World Health Organization-endorsed strategies for improving the diagnosis of tuberculosis (TB): same-day microscopy and Xpert MTB/RIF (Cepheid, USA). METHODS We created a compartmental transmission model of TB in a representative African community, fit to the regional incidence and mortality of TB and HIV. We compared the population-leve...

متن کامل

Performance of Xpert® MTB/RIF among tuberculosis outpatients in Lilongwe, Malawi

BACKGROUND Xpert® MTB/RIF is a molecular test for the detection of Mycobacterium tuberculosis and rifampicin resistance. It is considered to be a great advance over smear microscopy and culture. However, there is very little information regarding the performance characteristics of Xpert MTB/RIF in Malawi. OBJECTIVE We aimed to evaluate the performance of Xpert MTB/RIF in a Malawian setting. ...

متن کامل

Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice

The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hawai'i journal of medicine & public health : a journal of Asia Pacific Medicine & Public Health

دوره 77 2  شماره 

صفحات  -

تاریخ انتشار 2018