Imaging lung perfusion.

نویسندگان

  • Susan R Hopkins
  • Mark O Wielpütz
  • Hans-Ulrich Kauczor
چکیده

From the first measurements of the distribution of pulmonary blood flow using radioactive tracers by West and colleagues (J Clin Invest 40: 1-12, 1961) allowing gravitational differences in pulmonary blood flow to be described, the imaging of pulmonary blood flow has made considerable progress. The researcher employing modern imaging techniques now has the choice of several techniques, including magnetic resonance imaging (MRI), computerized tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT). These techniques differ in several important ways: the resolution of the measurement, the type of contrast or tag used to image flow, and the amount of ionizing radiation associated with each measurement. In addition, the techniques vary in what is actually measured, whether it is capillary perfusion such as with PET and SPECT, or larger vessel information in addition to capillary perfusion such as with MRI and CT. Combined, these issues affect quantification and interpretation of data as well as the type of experiments possible using different techniques. The goal of this review is to give an overview of the techniques most commonly in use for physiological experiments along with the issues unique to each technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging

Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...

متن کامل

کاربرد میکرو ذرات چیتوزان – تکنسیوم-99 در تصویربرداری ریه موش: یک گزارش کوتاه

Background and Objective: In nuclear medicine, lung perfusion scintigraphy is performed by radiolabeled particles, 99 mTc-albumin macroaggregated. Synthesizing of the particles has some difficulties. In order to resolve this problem, chitosan microparticles were used as an alternative choice.  Materials and Methods: The qualitative control tests including: the determining particles size...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

Preparation of human serum albumin microspheres (MSA) kit for lung imaging in Iran [Persian]

Radiolabeled Microspheres of human serum albumin (MSA) is of great importance in the analysis of regional lung perfusion. Preparation of MSA kit has been installed in our Division recently is carried out in two stages: 1. Production of albumin sphere particles with suitable sizes by using the spinning disk technique. 2. Formulation of MSA as a radiopharmacutical kit. So it can be labelled...

متن کامل

The value of myocardial perfusion imaging with Tc-99m MIBI for the prediction of perfusion improvement after percutaneous transluminal coronary angioplasty

  Introduction: Percutaneous transluminal coronary angioplasty (PTCA) is an effective method for revascularizing of stenotic coronary vessels. Lack of response to this treatment, either in symptomatic or asymptomatic patients, is usually due to incomplete revascularization, restenosis, and/or irreversibility of myocardial perfusion. Introduction of a noninvasive metho...

متن کامل

Reverse mismatched ventilation-perfusion pulmonary imaging with accumulation of technetium-99m-DTPA in a mucous plug in a main bronchus: a case report.

The phenomenon of reverse mismatched ventilation-perfusion on pulmonary scintigraphy is a fairly common occurrence. We present a patient who was experiencing decreasing oxygen saturation and had a reverse mismatched ventilation-perfusion imaging pattern associated with radiotracer retention in a main bronchus. Technetium-99m-DTPA aerosol lung imaging showed tracer retention in the trachea and r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 113 2  شماره 

صفحات  -

تاریخ انتشار 2012