ATP-EMTP study of current differential protection with synchronization and fault location functions

نویسندگان

  • M. M. Saha
  • J. Izykowski
  • E. Rosolowski
چکیده

-This paper considers fault location and analytical synchronization of two-end measurements functions as embedded into a current differential protective relay. As a result of that, incomplete two-end measurements, i.e. three-phase currents measured at both line ends, while three-phase voltage only from only one end are considered for processing. Fault location and synchronization formulae are derived with considering a distributed-parameter model of a transposed overhead power line. The performed ATP-EMTP based evaluation proved the validity of the presented algorithms and their high accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص بین جریان خطای داخلی و جریان هجومی در ترانسفورماتور با استفاده از روش آشوب

In this paper, a new method has been presented for differential protection of power transformers.  In this approach, chaotic method has been used for distinguishing of inrush current from internal fault current of the transformer. The proposed algorithm has been designed based on analysis of harmonic components of the differential current of the transformer due to internal faults and inrus...

متن کامل

فاصله یابی خطا در خطوط انتقال نیرو با سه پایانه در حوزه زمان با استفاده از اندازه گیریهای همزمان و مدل گسترده خط انتقال

Conventional fault location methods using voltages and currents of one terminal are not applicable to multiterminal transmission lines. So far some techniques have been presented to solve fault location problem for multi-terminal transmission lines. In these methods, lumped or distributed frequency domain models of transmission lines have been used. In multi terminal lines, faulty section shoul...

متن کامل

Performance Evaluation of Fault Location Algorithm for Protection of Series Compensated Transmission Line

In this paper, performance evaluation of different schemes for location of fault in series compensated transmission lines are presented. A fault location algorithm using two end measurements and another fault location algorithm using one end measurements for transmission lines with series compensator at midpoint are simulated and results are obtained. Both the schemes are compared on the basis ...

متن کامل

A New Multiterminal Fault Location Algorithm Embedded in Line Current Differential Relays

Accurate fault location on transmission lines becomes increasingly beneficial by reducing outage times and allowing faster restoration of scarce power system assets back into service. Having natural access to synchronized remote current data, line current differential protection schemes can incorporate multiterminal fault location algorithms, allowing for more accurate fault location compared w...

متن کامل

Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

The increased accuracy into the fault’s detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids’ lines are presented. The double-end synchronized data algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013