Motion Estimation Model for Cardiac and Respiratory Motion Compensation

نویسندگان

  • Sebastian Kaeppler
  • Alexander Brost
  • Martin Koch
  • Wen Wu
  • Felix Bourier
  • Terrence Chen
  • Klaus Kurzidim
  • Joachim Hornegger
  • Norbert Strobel
چکیده

Catheter ablation is widely accepted as the best remaining option for the treatment of atrial fibrillation if drug therapy fails. Ablation procedures can be guided by 3-D overlay images projected onto live fluoroscopic X-ray images. These overlay images are generated from either MR, CT or C-Arm CT volumes. As the alignment of the overlay is often compromised by cardiac and respiratory motion, motion compensation methods are desirable. The most recent and promising approaches use either a catheter in the coronary sinus vein, or a circumferential mapping catheter placed at the ostium of one of the pulmonary veins. As both methods suffer from different problems, we propose a novel method to achieve motion compensation for fluoroscopy guided cardiac ablation procedures. Our new method localizes the coronary sinus catheter. Based on this information, we estimate the position of the circumferential mapping catheter. As the mapping catheter is placed at the site of ablation, it provides a good surrogate for respiratory and cardiac motion. To correlate the motion of both catheters, our method includes a training phase in which both catheters are tracked together. The training information is then used to estimate the cardiac and respiratory motion of the left atrium by observing the coronary sinus catheter only. The approach yields an average 2-D estimation error of 1.99 ± 1.20 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Advances in 4D Gated Cardiac PET Imaging for Image Quality Improvement and Cardiac Motion and Contractility Estimation

Quantitative four-dimensional (4D) image reconstruction methods with respiratory and cardiac motion compensation are an active area of research in ECT imaging, including SPECT and PET. They are the extensions of three-dimensional (3D) statistical image reconstruction methods with iterative algorithms that incorporate accurate models of the imaging process and provide significant improvement in ...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

A Simplified Pipeline for Motion Correction in Dual Gated Cardiac PET

Positron Emission Tomography (PET) is a nuclear imaging technique of increasing importance e.g. in cardiovascular investigations. However, cardiac and respiratory motion of the patient degrade the image quality due to acquisition times in the order of minutes. Reconstructions without motion compensation are prone to spatial blurring and affected attenuation correction. These effects can be redu...

متن کامل

New adaptive interpolation schemes for efficient meshbased motion estimation

Motion estimation and compensation is an essential part of existing video coding systems. The mesh-based motion estimation (MME) produces smoother motion field, better subjective quality (free from blocking artifacts), and higher peak signal-to-noise ratio (PSNR) in many cases, especially at low bitrate video communications, compared to the conventional block matching algorithm (BMA). Howev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012