Further observations on the ventricular echo phenomenon elicited in the human heart. Is the atrium part of the echo pathway?

نویسندگان

  • R M Schuilenburg
  • D Durrer
چکیده

SUMMARY In order to answer the question whether the atrium is a link in the pathway of ventricular reciprocation or whether the A-V node itself is the reflection point of the echo, a special stimulation program was followed in six patients in whom ventricular echo beats with stable time relations could be elicited by regular pacing of the right ventricle or by the application of appropriately timed right ventricular premature beats during regular pacing of the right ventricle. In these experiments the atrial septum was stimulated earlier than the expected arrival at the atrium of the retrograde impulse in the course of the echo sequence. The influence of stepwise (steps of 5 msec) advancing of this atrial "preexcitation" on the timing of the ventricular echo beat was studied. We found that the atrial septum could be preexcited without interfering with the ventricular echo beat time relations over a time interval less than 5 msec in one patient, less than 10 msec in one, less than 20 msec in two, and less than 30 msec in two cases. When the time interval needed for the stimulated atrial impulse to reach the atrionodal margin is taken into account, it seems likely that the atrium participated in the echo pathway in the four cases with minimal atrial preexcitation intervals of 20 msec or less, and that in the two cases with a minimal atrial preexcitation intelval of 30 msec the echo reflection point was localized in the upper part of the A-V node. IN RECENT years intracavitary stimulation studies have outlined the conditions favoring the occurrence of the ventricular echo phenomenon in the intact human heart.1-4 The outcome of these studies suggested that the mechanism of reciprocation in the human heart could be explained with the concept of longitudinal dissociation in the upper part of the A-V junction.5-7 These clinical investigations did not give an answer to the question duction Ventricular reciprocation Stimulation experiments whether the atrium is a link in the echo circuit, as advocated by Mendez and co-workers ,8 or whether the point of reflection of the echo is located within the A-V node, as proposed by Mignone and Wallace.9 In six patients with ventricular reciprocation elicited by appropriately timed stimulation of the ventricles, we tried to obtain an answer to this question by stimulaton of the atrium earlier than the excitation of the atrium expected in the course of the …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular echo beats in the human heart elicited by induced ventricular premature beats.

SUMMARY In three patients, all having as their only hemodynamic abnormality an elevated cardiac index at rest, ventricular echo beats could be elicited by ventricular premature beats induced during regular driving of the ventricle. The occurrence of ventricular echo beats was in each case limited to a small delay-range of the premature beat. Retardation of retrograde conduction of the premature...

متن کامل

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

Performance of Nondestructive Sonic Echo Testing Method on Partially Dismantled Unknown Wood Bridge Foundations; A Case Study

Sonic Echo (SE) testing method is a well-known, versatile method to gather information pertaining to unknown bridge foundations. Many studies on the applicability and methodology improvement of SE tests to evaluate individual piles and foundations supporting the superstructure have been reported previously. However, there is a rare opportunity for obtaining the performance of SE tests without t...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Some Characteristics of Ventricular Echoes.

• Two features of A-V transmission previously attributed to a dual conduction system; namely, "abnormal" delay in the A-V propagation of early premature atrial responses, and alteration of the configuration of the corresponding ventricular electrograms, have been adequately explained as due to aberrant conduction within the intraventricular conduction system,and more specifically as the result ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1972