Clinical evaluation of the digene hybrid capture II test and the COBAS AMPLICOR monitor test for determination of hepatitis B virus DNA levels.

نویسندگان

  • He-Jun Yuan
  • Man-Fung Yuen
  • Danny Ka-Ho Wong
  • Simon Siu-Man Sum
  • Ching-Lung Lai
چکیده

The measurement of hepatitis B virus (HBV) DNA is important for the assessment of liver disease and treatment efficacy. Most commercially available assays for the determination of HBV DNA levels have limited linear ranges. This study was performed to evaluate the clinical performance of the Digene Hybrid Capture II (Digene HC II assay) and the COBAS AMPLICOR Monitor test (COBAS-AM assay), with special emphasis on anti-HBV e antigen (HBeAg)-positive patients with low HBV DNA levels. A total of 425 Chinese patients with chronic hepatitis B were recruited. A total of 107 patients were HBeAg positive, and 318 patients were HBeAg negative. The Digene HC II assay and the COBAS-AM assay had similar intra-assay and interassay variabilities. A total of 264 patients (62.1%) had HBV DNA levels undetectable by the Digene HC II assay, and 47 patients (11.1%) had HBV DNA levels undetectable by the COBAS-AM assay (P < 0.001). For the 161 patients with HBV DNA levels detectable by the Digene HC II assay, the HBV DNA levels obtained by the Digene HC II assay and by the COBAS-AM assay showed an excellent correlation (r = 0.95; P < 0.001). The linear ranges of the Digene HC II assay and the COBAS-AM assay marginally overlapped. Before HBV DNA levels could be determined by the COBAS-AM assay, predilution had to be performed for 158 of 161 patients (98.1%) with HBV DNA levels detectable by the Digene HC II assay and for 10 of 264 patients (3.8%) with HBV DNA levels undetectable by the Digene HC II assay. The cost for assaying each serum sample by using different strategies was calculated. The COBAS-AM assay was more sensitive than the Digene HC II assay and more suitable for monitoring low levels of HBV viremia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter evaluation of the VERSANT hepatitis B virus DNA 3.0 assay.

The VERSANT hepatitis B virus (HBV) 3.0 Assay (branched DNA [bDNA]) (referred to herein as VERSANT 3.0) was evaluated at four external sites for analytical sensitivity, specificity, reproducibility, linearity of quantification, and limits of detection. In addition, each of the test evaluation sites provided HBV DNA-positive clinical samples that were previously analyzed by one of three commerci...

متن کامل

Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA.

The COBAS AMPLIPREP instrument for automated sample preparation has recently been introduced. In this study, the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test, which includes this new molecular device, was evaluated and compared to the COBAS AMPLICOR HCV MONITOR test, which includes a manual extraction protocol. Interassay and intra-assay variation, precision, and linearity were determined, a...

متن کامل

Performance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.

A clinical evaluation of an automated quantitative PCR assay, the COBAS AMPLICOR HCV MONITOR test, version 2.0 (v2.0), was carried out to assess the performance of this test in comparison with that of the previous, manual version, the AMPLICOR HCV MONITOR test, and with that of nested PCR. Serial dilutions of serum samples infected with genotype 1b, 2a, or 3, as well as synthetic RNA transcript...

متن کامل

Evaluation of the invader assay for genotyping hepatitis C virus.

The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5' noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, ...

متن کامل

Clinical evaluation of the COBAS Amplicor HBV monitor test for measuring serum HBV DNA and comparison with the Quantiplex branched DNA signal amplification assay in Taiwan.

AIMS To evaluate the performance characteristics and clinical usefulness of the COBAS Amplicor HBV monitor (COBAS-AM) test in Taiwan and to examine its correlation with the Quantiplex branched DNA signal amplification (bDNA) assay for measuring serum hepatitis B virus (HBV) DNA concentrations. METHODS HBV DNA was measured by the COBAS-AM test in 149 sera from chronic HBV infected patients tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 8  شماره 

صفحات  -

تاریخ انتشار 2004