Ex vivo electrical impedance measurements on excised hepatic tissue from human patients with metastatic colorectal cancer.

نویسندگان

  • S Prakash
  • M P Karnes
  • E K Sequin
  • J D West
  • C L Hitchcock
  • S D Nichols
  • M Bloomston
  • S R Abdel-Misih
  • C R Schmidt
  • E W Martin
  • S P Povoski
  • V V Subramaniam
چکیده

Point-wise ex vivo electrical impedance spectroscopy measurements were conducted on excised hepatic tissue from human patients with metastatic colorectal cancer using a linear four-electrode impedance probe. This study of 132 measurements from 10 colorectal cancer patients, the largest to date, reports that the equivalent electrical conductivity for tumor tissue is significantly higher than normal tissue (p < 0.01), ranging from 2-5 times greater over the measured frequency range of 100 Hz-1 MHz. Difference in tissue electrical permittivity is also found to be statistically significant across most frequencies. Furthermore, the complex impedance is also reported for both normal and tumor tissue. Consistent with trends for tissue electrical conductivity, normal tissue has a significantly higher impedance than tumor tissue (p < 0.01), as well as a higher net capacitive phase shift (33° for normal liver tissue in contrast to 10° for tumor tissue).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening

Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...

متن کامل

ارزیابی فراوانی جهش‌های ژن KRAS در بیماران ایرانی مبتلا به سرطان کولورکتال

Background: Kirsten rat sarcoma (KRAS) gene is a target of genetic alterations which are diagnostic and prognostic biomarkers in patients with metastatic colorectal cancer who are treated with monoclonal anti-EGFR antibodies such as cetuximab and panitumumab. KRAS mutations are seen in 35-42% of patients with colorectal cancer. The high frequency of these mutations in colorectal cancer represen...

متن کامل

Bladder Cancer Detection Using Electrical Impedance Technique (Tabriz Mark 1)

Bladder cancer is the fourth most common malignant neoplasm in men and the eighth in women. Bladder pathology is usually investigated visually by cystoscopy. In this technique, biopsies are obtained from the suspected area and then, after needed procedure, the diagnostic information can be taken. This is a relatively difficult procedure and is associated with discomfort for the patient and morb...

متن کامل

Electrical impedance characterization of normal and cancerous human hepatic tissue.

The four-electrode method was used to measure the ex vivo complex electrical impedance of tissues from 14 hepatic tumors and the surrounding normal liver from six patients. Measurements were done in the frequency range 1-400 kHz. It was found that the conductivity of the tumor tissue was much higher than that of the normal liver tissue in this frequency range (from 0.14 +/- 0.06 S m(-1) versus ...

متن کامل

Behavioral profiling of human transitional cell carcinoma ex vivo.

Outcome studies of many types of cancer have revealed that tumors of indistinguishable histologic appearance may differ significantly in aggressiveness and in their response to therapy. A strategy that would enable early identification of patients at high risk for disease progression and allow screening of multiple therapeutic agents simultaneously for efficacy would improve clinical management...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2015