Phosphodiester content measured in human liver by in vivo 31P MR spectroscopy at 7 tesla
نویسندگان
چکیده
PURPOSE Phosphorus (31 P) metabolites are emerging liver disease biomarkers. Of particular interest are phosphomonoester and phosphodiester (PDE) "peaks" that comprise multiple overlapping resonances in 31 P spectra. This study investigates the effect of improved spectral resolution at 7 Tesla (T) on quantifying hepatic metabolites in cirrhosis. METHODS Five volunteers were scanned to determine metabolite T1 s. Ten volunteers and 11 patients with liver cirrhosis were scanned at 7T. Liver spectra were acquired in 28 min using a 16-channel 31 P array and 3D chemical shift imaging. Concentrations were calculated using γ-adenosine-triphosphate (γ-ATP) = 2.65 mmol/L wet tissue. RESULTS T1 means ± standard deviations: phosphatidylcholine 1.05 ± 0.28 s, nicotinamide-adenine-dinucleotide (NAD+ ) 2.0 ± 1.0 s, uridine-diphosphoglucose (UDPG) 3.3 ± 1.4 s. Concentrations in healthy volunteers: α-ATP 2.74 ± 0.11 mmol/L wet tissue, inorganic phosphate 2.23 ± 0.20 mmol/L wet tissue, glycerophosphocholine 2.34 ± 0.46 mmol/L wet tissue, glycerophosphoethanolamine 1.50 ± 0.28 mmol/L wet tissue, phosphocholine 1.06 ± 0.16 mmol/L wet tissue, phosphoethanolamine 0.77 ± 0.14 mmol/L wet tissue, NAD+ 2.37 ± 0.14 mmol/L wet tissue, UDPG 2.00 ± 0.22 mmol/L wet tissue, phosphatidylcholine 1.38 ± 0.31 mmol/L wet tissue. Inorganic phosphate and phosphatidylcholine concentrations were significantly lower in patients; glycerophosphoethanolamine concentrations were significantly higher (P < 0.05). CONCLUSION We report human in vivo hepatic T1 s for phosphatidylcholine, NAD+ , and UDPG for the first time at 7T. Our protocol allows high signal-to-noise, repeatable measurement of metabolite concentrations in human liver. The splitting of PDE into its constituent peaks at 7T may allow more insight into changes in metabolism. Magn Reson Med 78:2095-2105, 2017. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
منابع مشابه
Characterization of the human prostate by in vivo P MR spectroscopic imaging at 7 Tesla
Introduction: The metabolism of the human prostate gland is an important subject of study in the determination of pathologies as benign hyperplasia and prostate cancer. Choline compounds involved in phospholipid metabolism may be specific biomarkers for tumor presence and malignancy and can be studied by P MR spectroscopy (1). At a magnetic field strength of 7 Tesla the spectral resolution of i...
متن کامل31P-magnetic resonance spectroscopy (31P-MRS) of human allografts after renal transplantation.
BACKGROUND 31P-Magnetic resonance spectroscopy (31P-MRS) can be used as a non-invasive tool for measuring the relative intracellular concentrations of several phosphorus metabolites in different organs. Various pathological conditions are characterized by different metabolic patterns. We studied the value of 31P-MRS after renal transplantation with both an uneventful and a clinically complicate...
متن کاملIn-vivo31P-MRS of skeletal muscle and liver: A way for non-invasive assessment of their metabolism
In addition to direct assessment of high energy phosphorus containing metabolite content within tissues, phosphorus magnetic resonance spectroscopy (31P-MRS) provides options to measure phospholipid metabolites and cellular pH, as well as the kinetics of chemical reactions of energy metabolism in vivo. Even though the great potential of 31P-MR was recognized over 30 years ago, modern MR systems...
متن کاملGlycerophosphocholine and Glycerophosphoethanolamine Are Not the Main Sources of the In Vivo 31P MRS Phosphodiester Signals from Healthy Fibroglandular Breast Tissue at 7 T
PURPOSE The identification of the phosphodiester (PDE) (31)P MR signals in the healthy human breast at ultra-high field. METHODS In vivo (31)P MRS measurements at 7 T of the PDE signals in the breast were performed investigating the chemical shifts, the transverse- and the longitudinal relaxation times. Chemical shifts and transverse relaxation times were compared with non-ambiguous PDE signa...
متن کاملHuman in-vivo 31P MR Spectroscopy of Benign and Malignant Breast Tumors
OBJECTIVE To assess the potential clinical utility of in-vivo 31P magnetic resonance spectroscopy (MRS) in patients with various malignant and benign breast lesions. MATERIALS AND METHODS Seventeen patients with untreated primary malignant breast lesions (group I), eight patients with untreated benign breast lesions (group II) and seven normal breasts (group III) were included in this study. ...