Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.
نویسندگان
چکیده
PURPOSE To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to LOCS III, nuclear opalescence was divided in six groups. Patients were evaluated by the Pentacam Scheimpflug System for the mean lens density using the Pentacam lens densitometry program (PLDP), the Pentacam Nucleus Staging (PNS) mean value and the PNS cataract grading score. RESULTS A positive correlation between the mean values of lens density and LOCS III classification, considering groups 1 to 5, could be noticed with PLDP and PNS mean value. The mean values between the groups were similar using the PLDP and the PNS mean value. However, when the PNS cataract grading score was evaluated, there was low correspondence with LOCS III classification. CONCLUSION Pentacam Scheimpflug device offers an objective measure of the lens nuclear density on nuclear cataracts. PLDP and the PNS mean value were both useful to evaluate age-related nuclear cataract up to LOCS III group 5.
منابع مشابه
Anterior Segment Parameters Using Pentacam and Prediction of Corneal Endothelial Cell Loss after Cataract Surgery
PURPOSE We evaluated various preoperative anterior segment parameters measured with a Pentacam rotating Scheimpflug camera and compared them with those of conventional methods. We also evaluated the effect of different parameters on corneal endothelial cells after cataract surgery. METHODS Pentacam examination was performed in 88 eyes from 88 patients to evaluate central anterior chamber dept...
متن کاملScheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract.
PURPOSE To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN Retrospective single-center study. METHODS In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam H...
متن کاملQuantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT) with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading
Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT) with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III) lens grading and corrected distance visual acuity (BCVA). Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were a...
متن کاملClinical importance of the lens opacities classification system III (LOCS III) in phacoemulsification.
The aim of this study was to compare the correlation of features of cataracts graded by the Lens Opacities Classification System, version III (LOCS III) with recorded operative characteristics during the phacoemulsification. The retrospective study included 245 cases operated on by a single surgeon from October 2003 to March 2004. The cataract was graded at the biomicroscope using the 4 grading...
متن کاملGrading nuclear cataract: reproducibility and validity of a new method.
AIMS To assess the reproducibility and validity of a new instrument for grading nuclear cataract-the laser slit lamp, by comparison with an established method of lens grading-the Lens Opacities Classification System III (LOCS III). METHODS 62 volunteers (113 eyes) were examined on two occasions. At each visit, a video image of the anterior segment was captured with the laser slit lamp and sto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 74 2 شماره
صفحات -
تاریخ انتشار 2011