Reconstruction of the Terminal of an Abandoned Fractured Unipolar Coronary Sinus Lead: a Feasible Solution to Restore Effective Cardiac Resynchronization Therapy
نویسندگان
چکیده
Complications related to coronary sinus lead are not infrequent in recipients of cardiac resynchronization devices. We describe the case of a patient with a biventricular implantable cardioverter defibrillator with persistent phrenic nerve stimulation, previous coronary sinus lead fracture, and severe left subclavian vein stenosis. The reimplantation of a new coronary sinus lead on the left side, ipsilateral to the original implant, was unsuccessful. In order to avoid more complex and risky procedures, we performed the repair of the fractured abandoned lead with the reconstruction of the unipolar lead terminal. Effective biventricular pacing was obtained with satisfactory electrical parameters and it was maintained at twelve months follow-up.
منابع مشابه
Development of a technique for left ventricular endocardial pacing via puncture of the interventricular septum.
BACKGROUND Left ventricular (LV) pacing through the coronary sinus is the standard approach for cardiac resynchronization therapy. When this route is unavailable, the alternatives have major limitations. LV endocardial pacing through the interventriuclar septum may offer a simpler solution. We describe an initial case series to demonstrate technical feasibility and to describe our refinement of...
متن کاملObstacles preventing biventricular pacing mitigated with lead extraction and His bundle pacing to achieve effective cardiac resynchronization
Introduction Cardiac resynchronization therapy (CRT) achieved by implanting a lead via the coronary sinus (CS) system significantly improves well-being, symptoms, morbidity, and mortality in appropriately selected populations with advanced heart failure (HF) or pacing-induced cardiomyopathy. Despite improvements in implant technique, lead design, and pacing algorithms, there still remains a sig...
متن کاملThree-dimensional coronary sinus reconstruction-guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantation.
AIMS Rotational angiography (RA) of the coronary sinus (CS) provides more anatomical insights compared with static angiographies. We evaluated intraprocedural three-dimensional (3D) CS reconstruction (RC) based on RA, using syngo(®) DynaCT Cardiac to guide CS lead implantation. METHODS AND RESULTS In 24 patients with indication for cardiac resynchronization therapy, intraprocedural RA and 3D ...
متن کاملSimulated extraction of stent stabilized coronary sinus leads
Cardiac resynchronization therapy (CRT) is an effective nonpharmacological therapeutic method for the treatment of selected patients with chronic heart failure with a wide QRS complex and mechanical dyssynchrony of cardiac ventricles. A new technique is used to stabilize the implanted coronary sinus lead in an appropriate position with an expanded coronary stent to maintain synchronous pacing o...
متن کاملSimple and effective solution for diaphragm pacing by that uses the transvenous femoral approach in a patient treated with cardiac resynchronization-defibrillator therapy: The wrapping method
The use of cardiac resynchronization therapy (CRT) has become widespread in patients with heart failure who meet the criteria for implantation. Coronary sinus lead positioning is important to provide the intended biventricular stimulation. Diaphragm pacing is a lead-related complication which occurs secondary to phrenic nerve stimulation. We present the case of a 58-year-old male patient who ha...
متن کامل