Ethylene oxide sterilisation--is it safe?

نویسندگان

  • E H Gillespie
  • J M Jackson
  • G R Owen
چکیده

Tests show that ethylene oxide penetrates and can sterilise long narrow tubes in a hospital ethylene oxide steriliser. Residual ethylene oxide levels in plastic tubing after sterilisation have been estimated. Although initially the levels were very high, storage for four days at room temperature reduced them to a safe level. If adequate controls of the sterilising process and storage are carried out, sterilisation by ethylene oxide is considered to be safe for new plastics and clean equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose-dependent reduction of bone inductive properties by ethylene oxide.

Sterilisation of demineralised bone matrix with ethylene oxide has been claimed to destroy the ability of bone matrix to induce new bone formation on intramuscular implantation. Other workers have routinely used ethylene oxide sterilised bone matrix for assays in rodents without detrimental effects. We studied the effects of various lengths of exposure to ethylene oxide gas, and found that bone...

متن کامل

Toxicity of ethylene oxide on the lens and on leukocytes: an epidemiological study in hospital sterilisation installations.

An epidemiological study was conducted in 55 subjects (mean age: 41) in hospitals to determine the prevalence of lens opacities and cataracts in workers exposed to ethylene oxide in six sterilisation units. The 21 exposed subjects over 45 were then compared with 16 non-exposed subjects, matched for age and sex. The relation between occupational exposure to ethylene oxide and white blood cell co...

متن کامل

[Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components].

PURPOSE OF THE STUDY Each method of sterilisation has some effect on the structure and properties of UHMWPE and thus also on joint replacement longevity. This study was designed to compare, using objective methods of measurement, several kinds of sterilisation and to recommend the one which has the best prospect for making joint replacements last longer. MATERIAL AND METHODS Two groups of UHM...

متن کامل

Oxidation of Ethylene to Ethylene Oxide by Selenium Modified Silver Catalyst

Oxidation of ethylene to ethylene oxide over silver catalyst and selenium modified catalyst has been studied by continuous flow and pulse techniques over the temperature range of 230-280 °C. The results are discussed in terms of reaction mechanisms proposed by others, rejecting mechanisms which involve peroxide formation. It has been shown that not only selectivity towards ethylene oxide pr...

متن کامل

Inactivation combined with cell lysis of Pseudomonas putida using a low pressure carbon dioxide microbubble technology

BACKGROUND Inactivation processes can be classified into non-thermal inactivation methods such as ethylene oxide and γ-radiation, and thermal methods such as autoclaving. The ability of carbon dioxide enriched microbubbles to inactivate Pseudomonas putida suspended in physiological saline, as a non-thermal sterilisation method, was investigated in this study with many operational advantages ove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 32 11  شماره 

صفحات  -

تاریخ انتشار 1979