Computerised intraocular lens calculation: clinical results and predictability.

نویسندگان

  • T Olsen
  • C U Andersen
  • H J Plesner
چکیده

The predictability of a theoretical, computer-assisted IOL calculation method and of the Sanders-Retzlaff-Kraff (SRK) method was evaluated from pre- and postoperative biometry in 110 cataractous patients subjected to a routine IOL calculation. With the theoretical method and the preoperative data the refraction was on the average 0.72 D (SD 0.78) more myopic than expected, an error which could be corrected for by (1) substituting the assumed postoperative chamber depth by the actual mean value and (2) adding 0.16 mm to the preoperative axial length. With the postoperative data the error was 0.05 D (SD 0.78) (p greater than 0.05). By the SRK method the refraction was 0.15 D (SD 0.71) and 0.37 D (SD 0.69) more hyperopic than expected with the pre- and the postoperative data respectively. These offset errors could be corrected for in either case by adjusting the assumed A constant in the SRK formula. With appropriate empirical corrections for offset errors the theoretical and the SRK method were similar in accuracy, that is, about 82% of the predictions within +/- 1 D, 99% within +/- 2 D, and 100% within +/- 3 D error. The variation in postoperative refraction after computerised IOL calculation was about one-third of the variation previously seen after implantation of standard power IOL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia.

OBJECTIVES To describe the refractive results of cataract surgery after photorefractive keratectomy (PRK) for patients with myopia, and to find a more accurate method to predict intraocular lens (IOL) power in these cases. DESIGN Nonrandomized, retrospective clinical study. PATIENTS AND METHODS Nine patients (15 eyes) who underwent cataract surgery after prior PRK to correct myopia were ide...

متن کامل

Predictability of Intraocular Lens Power Calculation After Simultaneous Pterygium Excision and Cataract Surgery

This study was aimed to assess the predictability of intraocular lens (IOL) power calculation after simultaneous pterygium excision and phacoemulsification with IOL implantation. We retrospectively reviewed the clinical charts of 60 eyes of 60 consecutive patients (mean age ± standard deviation, 73.5 ± 7.0 years) who developed pterygium and cataract. We determined visual acuity (logMAR), manife...

متن کامل

Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It

PURPOSE To evaluate the refractive predictability of a partial coherence interferometry (PCI) biometry device (IOL Master) for cataract surgery and to investigate factors that may affect it. METHODS Retrospective review of 209 eyes from 151 patients that had undergone preoperative PCI biometry and an uneventful phacoemulsification cataract surgery with posterior chamber intraocular lens (IOL)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 1989