Short-term effect of transcatheter aortic valve implantation on QT dispersion.

نویسندگان

  • Haci Ahmet Kasapkara
  • Hüseyin Ayhan
  • Tahir Durmaz
  • Telat Keleş
  • Cenk Sari
  • Serdal Baştuğ
  • Cemal Köseoğlu
  • Bilge Duran Karaduman
  • Murat Akçay
  • Nihal Akar Bayram
  • Emine Bilen
  • Engin Bozkurt
چکیده

BACKGROUND/AIM Electrophysiological changes are observed following mechanical stretches due to pressure overload in patients with severe aortic stenosis (AS). The electrical instability occurs after depolarization and dispersion of repolarization. The aim of this study was to evaluate changes in ventricular repolarization following transcatheter aortic valve implantation (TAVI). MATERIALS AND METHODS Thestudypopulationincluded 100 consecutive patients with severe AS thatunderwent TAVI. Electrocardiography (ECG) was performed at baseline, immediately after TAVI, and 1 week after TAVI. RESULTS The mean age of the patients was 78.2 ± 7.2 years. Thirty-four (34%) of the patients were male and 66 (66%) were female. Compared to the baseline, mean QT dispersion (QTd) immediately after TAVI and 1 week after TAVI decreased significantly (82.8 ± 26.5,75.6 ± 25.2, and 65.8 ± 28.3, respectively, P < 0.001). Likewise, compared to the baseline, mean corrected QTd (QTcd) immediately after TAVI and 1 week after TAVI decreased significantly (84.7 ± 25.2, 76.7 ± 30.8, and 69.1 ± 31.4, respectively, P < 0.001). CONCLUSION QTd is indicative of heterogeneity of ventricular refractoriness and is prolonged in patients with AS. Following TAVI, a decrease in QTd might reduce the risk of ventricular arrhythmia in patients with severe AS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of transcatheter aortic valve implantation on QT dispersion in patients with aortic stenosis

BACKGROUND QT dispersion (QTd) is a predictor of ventricular arrhythmia. Ventricular arrhythmia is an important factor influencing morbidity and mortality in patients with aortic stenosis. Surgical aortic valve replacement reduced the QTd in this patients group. However, the effect of transcatheter aortic valve implantation (TAVI) on QTd in patients with aortic stenosis is unknown. The aim of t...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Transmural dispersion of repolarization: a complementary index for cardiac inhomogeneity

To the editor  We read the article written by Nuis, et al. The authors investigated the effects of transcatheter aortic valve implantation (TAVI) on corrected QT dispersion (cQTD) in severe aortic stenosis patients. They concluded that, 40% of patients had defective cQTD recovery at six months after the procedure and this was associated with increased late mortality risk. We would like to cont...

متن کامل

Short-long-short sequence-induced torsade de pointes after transcatheter aortic-valve implantation

The gold-standard treatment of symptomatic aortic stenosis (AS) is surgical aortic-valve replacement (SAVR); however, many patients owing to high operative risks are not candidates for this treatment (1). Hence, transcatheter aortic-valve implantation (TAVI) was introduced to be an alternative modality to SAVR. Because of older patient population and structural heart disease, TAVI patients may ...

متن کامل

A step forward parameter for the effects of transcatheter aortic valve implantation: transmural dispersion of repolarization

To the Editor We read the article " Effect of transcatheter aortic valve implantation on QT dispersion in patients with aortic stenosis " by Erkan, et al. [1] with great interest. In this study, they investigated the effect of transcatheter aortic valve implanta-tion (TAVI) on QT dispersion (QTd) in patients with symptomatic severe aortic stenosis. They reported that left ventricular mass index...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish journal of medical sciences

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2015