Sound transmission in the lung as a function of lung volume.

نویسندگان

  • T Bergstresser
  • D Ofengeim
  • A Vyshedskiy
  • J Shane
  • R Murphy
چکیده

We were interested in how the transmission of sound through the lung was affected by varying air content in intact humans as a method of monitoring tissue properties noninvasively. To study this, we developed a method of measuring transthoracic sound transit time accurately. We introduced a "coded" sound at the mouth and measured the transit time at multiple microphones placed over the chest wall by using a 16-channel lung sound analyzer (Stethographics). We used a microphone placed over the neck near the trachea as our reference and utilized cross-correlation analysis to calculate the transit times. The use of the coded sound, composed of a mix of frequencies from 130 to 150 Hz, greatly reduced the ambiguity of the cross-correlation function. The measured transit time varied from 1 ms at the central locations to 5 ms at the lung bases. Our results also indicated that transit time at all locations decreased with increasing lung volume. We found that these results can be described in terms of a model in which sound transmission through the lung is treated as a combination of free-space propagation through the trachea and a propagation through a two-phase system in the parenchyma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

Reduced Lung Function and Progression to Prediabetes: A Prospective Study

Objective: Prediabetes is a state that people have blood glucose levels higher than normal but still not in diabetes range. There is a close relationship between impaired lung function and diabetes mellitus (DM). Reduced lung function can be present before the clinical evidence of diabetes or insulin resistance. Materials and Methods: The total number of subjects in this longitudinal study was ...

متن کامل

Effects of Sodium Cromoglycate on Iranian Asthmatic Subjects Without Exposure to any Bronchoconstrictor agent

   Cromolyn sodium, a mast cell stabilizing agent, provides an immediate protective effect against the exercise-induced bronchoconstriction while being used before the exercise. However, cromolyn is ineffective in reversing asthmatic bronchospasm; it is used as a maintenance therapy and has a prophylactic role in chronic asthma.    The purpose of this study was to determine the extent of change...

متن کامل

Do Statins Improve Lung Function in Asthmatic Patients? A Randomized and Double-Blind Trial

      There are evidences that statins have anti-inflammatory effects beyond their cholesterol lowering properties. The study was conducted to assess the effects of atorvastatin on asthma as an inflammatory disease. Patients with moderate to severe asthma were entered this randomized, double blind, crossover clinical trial. The impact of oral atorvastatin (10 mg/day) on the lung function of nor...

متن کامل

Effects of Sodium Cromoglycate on Iranian Asthmatic Subjects Without Exposure to any Bronchoconstrictor agent

   Cromolyn sodium, a mast cell stabilizing agent, provides an immediate protective effect against the exercise-induced bronchoconstriction while being used before the exercise. However, cromolyn is ineffective in reversing asthmatic bronchospasm; it is used as a maintenance therapy and has a prophylactic role in chronic asthma.    The purpose of this study was to determine the extent of change...

متن کامل

The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test

Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2002