The predictive value of transcranial sonography in clinically diagnosed patients with early stage Parkinson's disease: comparison with DAT PET scans.

نویسندگان

  • Ping Liu
  • Xin Li
  • Fang-Fei Li
  • Qiao-Hong Ou-Yang
  • Hong-Xia Zhang
  • Tao Feng
چکیده

Early and correct diagnosis of Parkinson's disease (PD) is critical for patient counseling and therapeutic management. The diagnostic accuracy of transcranial sonography of substantia nigra (SN-TCS) for early stage PD patients remains controversial. Dopamine transporter (DAT) imaging is sensitive to detect presynaptic dopamine neuronal dysfunction, and has been studied as a diagnostic tool for degenerative Parkinsonism. To investigate the predictive value of SN-TCS for the DAT PET scans in clinically diagnosed early stage PD patients, we performed the SN-TCS and DAT Positron Emission Computed Tomography (PET) imaging examinations on 53 patients. Using the DAT PET results as clinical gold standard, the sensitivity and specificity of TCS was 68.75% and 40% respectively. The positive predictive value (PPV) of an abnormal TCS for an abnormal PET scan was 91.67%. However, the negative predictive value (NPV) for a normal PET scan was only 11.76%. The false negative rate was 31.25%. In 35 patients, the result of the SN-TCD was in accordance with the result of the DAT PET scan (Kappa=0.042, P>0.05). The consistency between SN-TCS and PET scans was poor. We conclude that SN-TCS would not be used as a diagnostic tool for early stage PD patients. Negative result of TCS could not exclude the diagnosis of PD. Further tests like DAT-PET is needed for validation. On the other hand, positive SN-TCS will reduce the added diagnostic value of a presynaptic neuronimaging scan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Transcranial Sonography Useful to Distinguish Scans Without Evidence of Dopaminergic Deficit Patients From Parkinson's Disease?

BACKGROUND Approximately 10% of patients clinically diagnosed with early Parkinson's disease (PD) subsequently have normal dopaminergic functional imaging. Transcranial sonography (TCS) has been shown to detect midbrain hyperechogenicity in approximately 90% of Parkinson's disease (PD) patients and 10% of the healthy population. The aim of this study was to investigate the prevalence of midbrai...

متن کامل

The predictive value of transcranial duplex sonography for the clinical diagnosis in undiagnosed parkinsonian syndromes: comparison with SPECT scans

BACKGROUND Transcranial duplex sonography (TCD) of the substantia nigra has emerged as a promising, non-invasive tool to diagnose idiopathic Parkinson's disease (IPD). However, its diagnostic accuracy in patients with undefined parkinsonism remains to be determined. In this study we determined the predictive value of TCD for the clinical diagnosis in undiagnosed parkinsonian syndromes. Addition...

متن کامل

Specificity and sensitivity of transcranial sonography of the substantia nigra in the diagnosis of Parkinson's disease: prospective cohort study in 196 patients

OBJECTIVE Numerous ultrasound studies have suggested that a typical enlarged area of echogenicity in the substantia nigra (SN+) can help diagnose idiopathic Parkinson's disease (IPD). Almost all these studies were retrospective and involved patients with well-established diagnoses and long-disease duration. In this study the diagnostic accuracy of transcranial sonography (TCS) of the substantia...

متن کامل

Predictive ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography for pathological complete response and prognosis after neoadjuvant chemotherapy in triple-negative breast cancer patients

Objective The mortality of patients with locally advanced triple-negative breast cancer (TNBC) is high, and pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) is associated with improved prognosis. This retrospective study was designed and powered to investigate the ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) to predict pat...

متن کامل

Prognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer

Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuroscience letters

دوره 582  شماره 

صفحات  -

تاریخ انتشار 2014