Performance of different materials as TSEE dosimeters in 90Sr+90Y radiation fields

نویسنده

  • M. L. Oliveira
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

90Sr-90Y biokinetics at incorporation determine the radiation burden to bone marrow.

The decay characteristics of 90Sr-90Y ensure that the mother and daughter nuclides exist in radioactive equilibrium, unless they get discriminated on the basis of their chemical properties, as it happens during metabolism. Although bone is the ultimate organ of deposition, the two nuclides arrive at this target organ over different biokinetic pathways. As 90Y is not excreted, it goes through tr...

متن کامل

Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including...

متن کامل

Measurement of 90sr in aqueous samples using liquid scintillation counting with full spectrum DPM method.

90Sr activity was measured with the full spectrum DPM (FS-DPM) counting method after plotting the quench correction curves of 90Sr and 90Y, and the FS-DPM method was applied to determine the 90Sr in liquid waste samples. The optimum regions of 90Sr and 90Y were set for measuring 90Sr with the dual label DPM (DL-DPM) method. The direct measurement of purified 90Sr with spectrum unfolding techniq...

متن کامل

Rapid 90Sr/90Y determination in water samples using a sequential injection method

We have developed a semiautomatic procedure based on a sequential injection method for 90Sr/90Y determination that allows their radiochemical separation in about 30 min. The method has been tested using 90Sr/90Y solutions with activities lower than 12 Bq. The source is eluted in a pH = 6.5 medium through a MnO2-impregnated cotton filter, where 9OY is preconcentrated in preference by adsorption....

متن کامل

Experimental Evaluation of Depth Dose by Exit Surface Diode Dosimeters for Off-Axis Wedged Fields in Radiation Therapy

Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. Materials and Methods A system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004