PURPOSE To develop a distortion correction method for echo planar imaging (EPI) that is able to measure dynamic changes in B0 . THEORY AND METHODS The approach we propose is based on single-echo EPI with a jittering of the echo time between two values for alternate time points. Field maps are calculated between phase images from adjacent volumes and are used to remove distortion from corresponding magnitude images. The performance of our approach was optimized using an analytical model and by comparison with field maps from dual-echo EPI. The method was tested in functional MRI experiments at 7T with motor tasks and compared with the conventional static approach. RESULTS Unwarping using our method was accurate even for head rotations up to 8.2°, where the static approach introduced errors up to 8.2 mm. Jittering the echo time between 19 and 25 ms had no measurable effect on blood oxygenation level-dependent (BOLD) sensitivity. Our approach reduced the distortions in activated regions to <1 mm and repositioned active voxels correctly. CONCLUSION This method yields accurate distortion correction in the presence of motion. No reduction in BOLD sensitivity was observed. As such, it is suitable for application in a wide range of functional MRI experiments. Magn Reson Med 76:1388-1399, 2016. © 2015 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion Weighted Imaging at 7T with STEAM-EPI and GRAPPA

Introduction: Diffusion Imaging at 7 Tesla has been quite a challenge. Standard diffusion sequences require long time to play diffusion gradients, especially for high b-values. This compromises higher intrinsic SNR [1]at 7T with shorter T2 relaxation. At 7T twice refocused spin echo [2] used for standard diffusion weighted imaging also suffers from high SAR. Magnetic field inhomogeneities that ...

متن کامل

Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.

Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...

متن کامل

Correcting High Order Eddy Current Induced Distortion for Diffusion Weighted Echo Planar Imaging

INTRODUCTION It is well known that diffusion weighted echo planar imaging (DW-EPI) often suffers from direction dependent distortions due to diffusion gradient generated eddy currents. These distortions, if not corrected, can lead to misregistration among DW images of different directions and inaccuracies in any post processing operations involving DW image combination. Dual spin echo DW-EPI [1...

متن کامل

Single-shot magnetic field mapping embedded in echo-planar time-course imaging.

A technique for acquiring magnetic field maps simultaneously with gradient-recalled echo-planar time-course data is described. This technique uses a trajectory in which the central part of k-space is collected twice. For a 64 x 64 image acquired with a 125-kHz bandwidth, a field map suitable for geometric correction can be collected simultaneously with the echo-planar time-course data in <70 ms...

متن کامل

Performance of single spin-echo and doubly refocused diffusion-weighted sequences in the presence of eddy current fields with multiple components.

Echo-planar diffusion-weighted images can display significant geometric distortions due to eddy current fields. Several preparation schemes have been proposed, which can null eddy currents with a single time constant. The aim of this work was to compare the performance of three such pulse sequences in the presence of multiple components and investigate whether affine registration is capable of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 76  شماره 

صفحات  -

تاریخ انتشار 2016