Early diastolic filling dynamics in diastolic dysfunction

نویسندگان

  • Gerard J King
  • Jerome B Foley
  • Faisal Almane
  • Peter A Crean
  • Michael J Walsh
چکیده

BACKGROUND The aim of the study was to determine the relationship between the rate of peak early mitral inflow velocity and the peak early diastolic mitral annular tissue velocities in normal controls and to compare them with subjects with diastolic dysfunction. METHODS The relationship between early passive diastolic transmitral flow and peak early mitral annular velocity in the normal and in diastolic dysfunction was studied. Two groups comprising 22 normal controls and 25 patients with diastolic dysfunction were studied. RESULTS Compared with the normal group, those with diastolic dysfunction had a lower E/A ratio (0.7 +/- 0.2 vs. 1.9 +/- 0.5, p < 0.001), a higher time-velocity integral of the atrial component (11.7 +/- 3.2 cm vs. 5.5 +/- 2.1 cm, p < 0.0001), a longer isovolumic relaxation time 73 +/- 12 ms vs. 94 +/- 6 ms, p < 0.01 and a lower rate of acceleration of blood across the mitral valve (549.2 +/- 151.9 cm/sec2 vs. 871 +/- 128.1 cm/sec2, p < 0.001). They also had a lower mitral annular relaxation velocity (Ea) (6.08 +/- 1.6 cm/sec vs 12.8 +/- 0.67 cm/sec, p < 0.001), which was positively correlated to the acceleration of early diastolic filling (R = 0.66), p < 0.05. CONCLUSIONS This investigation provides information on the acceleration of early diastolic filling and its relationship to mitral annular peak tissue velocity (Ea) recorded by Doppler tissue imaging. It supports not only the premise that recoil is an important mechanism for rapid early diastolic filling but also the existence of an early diastolic mechanism in normal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of LV diastolic function from color M-mode echocardiography.

OBJECTIVES this study evaluated early diastolic filling dynamics using a semiautomated objective analysis of filling velocities obtained from color M-mode echocardiography. BACKGROUND diastolic function can be evaluated from color M-mode echocardiography by measuring the early diastolic flow propagation velocity (Vp) from the slope of a single linear approximation of an isovelocity contour. H...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Left ventricular vortex formation is unaffected by diastolic impairment.

Normal left ventricular (LV) filling occurs rapidly early in diastole caused by a progressive pressure gradient within the ventricle and with a low left atrial pressure. This normal diastolic function is altered in patients with heart failure. Such impairment of diastolic filling is manifested as an abrupt deceleration of the early filling wave velocity. Although variations within the early fil...

متن کامل

Evaluation of left ventricular diastolic function with a dedicated cadmium-zinc-telluride cardiac camera: comparison with Doppler echocardiography.

AIMS To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND RESULTS Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardio...

متن کامل

Utility of B-natriuretic peptide in detecting diastolic dysfunction: comparison with Doppler velocity recordings.

BACKGROUND Although Doppler echocardiography has been used to identify abnormal left ventricular (LV) diastolic filling dynamics, inherent limitations suggest the need for additional measures of diastolic dysfunction. Because data suggest that B-natriuretic peptide (BNP) partially reflects ventricular pressure, we hypothesized that BNP levels could predict diastolic abnormalities in patients wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2003