Interferences study for Selenium determination using of on Liquid Nitrogen Trap Hydride generation atomic absorption Spectrometry
نویسنده
چکیده
A method has been developd determine selenium by hydride generation atomic absorption using nitrogen trapping technique. A series of experiments was performed to obtain the optimum condition. The results show that this method has the advantage of being sensitive, accurate, rapid and simple. Transition metal and other hydride forming elements interferences on the determination of selenium was studied. A substantial increase in the range of interference – free determination of selenium can be achieved by increasing the hydrochloride acid concentration .
منابع مشابه
Investigation of Poor Analytical Recovery Using Borosilicate Glass Containers in Selenium Determination by Atomic Absorption Spectrometry with Hydride Generation
Suminda Hapuarachchi and Thomas G. Chasteen* Department of Chemistry 1003 Bowers Boulevard, CFS317e Sam Houston State University Huntsville, TX 77340, USA E-mail: [email protected] Abstract The chemical interferences of Hg, Sn, Pb , Fe, Bi, and Te in the hydride generation atomic absorption spectrometry (HG-AAS) determination of selenium have been studied but interference from the glassware com...
متن کاملOn-line hyphenation of hydride generation with in situ trapping flame atomic absorption spectrometry for arsenic and selenium determination.
The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the opera...
متن کاملSpeciation of Arsenic(III)/Arsenic(V) and Selenium(IV)/Selenium(VI) Using Coupled Ion Chromatography– Hydride Generation Atomic Absorption Spectrometry
Simple analytical methods have been developed to speciate inorganic As and Se in the microgram per liter range using coupled ion chromatography–hydride generation atomic absorption spectrometry. Because of the differences in toxicity and adsorption behavior, determinations of the redox states arsenite, As(III), and arsenate, As(V), and selenite, Se(IV), and selenate, Se(VI), are important. Anio...
متن کاملA Critical Survey of Hydride Generation Techniques in Atomic Spectroscopy
Formation of the hydrides of antimony arsenic, bismuth, germanium, lead, selenium, tellurium and tin by reaction with sodium tetrahydroborate0 affords an excellent method for the separation of these elements as gases from a wide range of matrices. Excellent low limits of detection are attained when this separation method is combined with atomisation of the hydride in a heated quartz tube in the...
متن کاملInterferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry
Interferences of some metals in the determination of arsenic by hydride generation atomic absorption spectrometry utilizing a quartz tube atomizer were studied. The atomizers were coated under vacuum with Ni, Au, Pd and Cr. The arsenic signal was almost totally suppressed by all the metal coatings and thus the interferences from metal ions in the determination of arsenic were attributed both to...
متن کامل